BH GSO IEC 61204-7:2016

IEC 61204-7:2006
Bahraini Standard   Current Edition · Approved on 08 February 2016

Low-voltage power supplies, d.c. output - Part 7: Safety requirements

BH GSO IEC 61204-7:2016 Files

English null Pages
Current Edition Reference Language

BH GSO IEC 61204-7:2016 Scope

1.1.1 Equipment covered by this standard This part of IEC 61204 specifies the safety requirements for POWER SUPPLY units providing DC output(s) with or without auxiliary a.c. output(s) operating from a.c. or d.c. source voltages up to 600 V a.c. or 1 000 V d.c. (See exceptions in 1.1.3). NOTE Ringing generators used in telecoms applications are covered by this standard. This product standard covers both STAND-ALONE and COMPONENT POWER SUPPLY units as defined in this document. POWER SUPPLY units, which comply with the main body of this standard, satisfy the requirements of POWER SUPPLY units for use in or with IT equipment normally covered by IEC 60950:1999 and/or IEC 60950-1:2001. POWER SUPPLY units will also comply with the appropriate standard or application requirements given below if they also meet the additional requirements of the appropriate annex. PS-A Measurement, control and laboratory equipment normally covered by IEC 61010-1: 2001. PS-B Medical equipment (under consideration) – normally covered by IEC 60601-1:2005. NOTE This annex will be based on IEC 60601-1:2005 (Third Edition) PS-C Reserved for future use. PS-D Audio, Video and similar electronic apparatus – normally covered by IEC 60065:2001. PS-E DC Power and distribution equipment. This standard also covers DC-DC converters. Where no standards exist, use of this standard for other applications is not precluded. 1.1.2 Additional requirements Requirements additional to those specified in this standard may be necessary for: – POWER SUPPLIES intended for operation in special environments (for example, extremes of temperature; excessive dust, moisture or vibration; flammable gases; and corrosive or explosive atmospheres); – les ALIMENTATIONS destinées à être utilisées dans des véhicules, à bord de navires ou d’avions, ou dans les pays tropicaux; – les ALIMENTATIONS destinées à être utilisées dans des endroits où la pénétration de l'eau est possible; pour connaître les exigences et les essais applicables, se reporter à l'Annexe T/RD. L'attention est attirée sur le fait que, dans certains pays, les autorités imposent des exigences supplémentaires pour des raisons liées à la santé, à l’environnement et pour des raisons similaires. Les ALIMENTATIONS pour utilisation dans ou avec des installations de puissance peuvent devoir satisfaire aux exigences complémentaires de la CEI 62103:2003. 1.1.3 Exclusions Cette norme ne s’applique pas – aux groupes convertisseurs; – aux ALIMENTATIONS sans interruption (ASI) relatives à la CEI 62040-1-1:2004; – aux ALIMENTATIONS couvertes par la CEI 61558-1:2005 (c’est-à-dire ALIMENTATIONS comportant des transformateurs de sécurité fournissant une (des) sortie(s) TBTS (très basse tension de sécurité) ou TBTP (très basse tension de protection) conformément à la CEI 60364-4-41:2001 et aux ALIMENTATIONS destinées à être utilisées avec des produits domestiques et d’autres produits de consommation, à l’exception de ceux couverts par la CEI 60065:2001 et/ou la CEI 60950:1999; – aux transformateurs couverts par la CEI 61558-1:2005; – aux convertisseurs abaisseurs couverts par la CEI 61046-1-1:1991; – aux ALIMENTATIONS et aux convertisseurs destinés à être utilisés avec ou dans des produits couverts par la CEI 61347-2-2:2000. – POWER SUPPLIES intended to be used in vehicles, on board ships or aircraft, or in tropical countries; – POWER SUPPLIES intended for use where ingress of water is possible; for guidance on such requirements and on relevant testing, see annex T/RD. Attention is drawn to the fact that authorities in some countries impose additional requirements for health, environmental and similar reasons. POWER SUPPLIES for use in or with power installations may have to meet additional requirements of IEC 62103:2003. 1.1.3 Exclusions This standard does not apply to – motor-generator sets; – uninterruptible POWER SUPPLIES (UPS) to IEC 62040-1-1:2004; – POWER SUPPLIES covered by IEC 61558-1:2005 (i.e. POWER SUPPLY units incorporating safety isolating transformers providing SELV or PELV output(s) in accordance with IEC 60364-4-41:2001 and POWER SUPPLIES for use with household and other consumer products, except those covered by IEC 60065:2001 and IEC 60950:1999 and/or IEC 60950-1:2001; – transformers covered by IEC 61558-1:2005; – step-down converters covered by IEC 60146-1-1:1991; – POWER SUPPLIES and converters for use with or in products covered by IEC 61347-2-2:2000.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 63522-32:2026
IEC 63522-32:2025 
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC TR 63411:2026
IEC TR 63411:2025 
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 60884-2-7:2026
IEC 60884-2-7:2025 
Gulf Standard
Plugs and socket-outlets for household and similar purposes - Part 2-7: Particular requirements for cord extension sets
GSO ISO 20816-21:2026
ISO 20816-21:2025 
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines