BH GSO IEC 61847:2016

IEC 61847:1998
Bahraini Standard   Current Edition · Approved on 10 February 2016

Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics

BH GSO IEC 61847:2016 Files

English null Pages
Current Edition Reference Language

BH GSO IEC 61847:2016 Scope

This International Standard specifies: – the essential non-thermal output characteristics of ultrasonic surgical units; NOTE 1 – One of the parameters of interest is output acoustic power. This standard addresses only the lowfrequency (under 100 kHz) component of the total delivered energy. The high-frequency component, which probably relates to cavitation developed at the tip, is not addressed (see A.4). – methods of measurement of these output characteristics; – those characteristics which should be declared by the manufacturers of such equipment. NOTE 2 – In the interest of clarity, this standard does not address all of the complex surfaces and shapes possible for applicator tips. A straight tubular shape is used in the description of the parameters and measurements to be made. It is left to the user of this standard to adapt the basic methodology described to more complex designs if required. This International Standard is applicable to equipment which meets the requirements of a, b and c below: a) ultrasonic surgical systems operating in the frequency range 20 kHz to 60 kHz; and b) ultrasonic surgical systems, whose use is the fragmentation or cutting of human tissue, whether or not those effects are delivered in conjunction with tissue removal or coagulation; and c) ultrasonic surgical systems, in which an acoustic wave is conducted by means of a specifically designed wave guide to deliver energy to the surgical site. NOTE 3 – Examples of these types of systems are surgical aspirators, intracorporeal lithotripters, end-cutting devices etc. This International Standard is not applicable to: – lithotripsy equipment which uses extracorporeally induced pressure pulses, focussed through liquid conducting media and the soft tissues of the body; – surgical devices used as part of the therapeutic process (hyperthermia systems); – surgical devices whose acoustic application areas are not at the end of a longitudinally vibrating applicator tip and therefore would not fit the monopole model used in this standard. This International Standard does not deal with the effectiveness or safety of ultrasonic surgical systems. NOTE 4 – Throughout this standard, the term accuracy means the overall uncertainty expressed at the 95%confidence level.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025 
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025 
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC 63522-32:2026
IEC 63522-32:2025 
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC TS 62600-301:2026
IEC TS 62600-301:2019 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 301: River energy resource assessment