This part of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV,

for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response

as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1 _ 109 m?2_s?1,

corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv_h?1.

This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference

radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and

ISO 8529-3.

The reference radiations specified are the following:

_ neutrons from radionuclide sources, including neutrons from sources in a moderator;

_ neutrons produced by nuclear reactions with charged particles from accelerators;

_ neutrons from reactors.

In view of the methods of production and use of them, these reference radiations are divided, for the purposes of

this part of ISO 8529, into the following two separate sections.

_ In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutronmeasuring

devices. These sources should be used by laboratories engaged in the routine calibration of

neutron-measuring devices, the particular design of which has already been type tested.

_ In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi

monoenergetic spectra are specified for determining the response of neutron-measuring devices as a function

of neutron energy. Since these reference radiations are produced at specialized and well equipped

laboratories, only the minimum of experimental detail is given.

For the conversion of neutron fluence into the quantities recommended for radiation protection purposes,

conversion coefficients have been calculated based on the spectra presented in normative annex A and using the

fluence-to-dose-equivalent conversion coefficients as a function of neutron energy as given in ICRP Publication 74

and ICRU Report 57.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
BH GSO 150-2:2015
GSO 150-2:2013 
مواصفة قياسية بحرينية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
BH GSO 2055-1:2016
GSO 2055-1:2015 
لائحة فنية بحرينية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال
GSO 2055-1:2015
 
لائحة فنية خليجية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

ISO 16408:2025
 
مواصفة قياسية دولية
Dentistry — Oral care products — Oral rinses
ISO 16383-1:2025
 
مواصفة قياسية دولية
Geotechnical investigation and testing — Laboratory testing of rock — Part 1: Determination of water content
ISO 2361:2025
 
مواصفة قياسية دولية
Electrodeposited nickel coatings on magnetic and non-magnetic substrates — Measurement of coating thickness — Magnetic method
ISO/TS 6226:2025
 
مواصفة قياسية دولية
Health informatics — Reference architecture for syndromic surveillance systems for infectious diseases