ISO 12417-1:2024

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٠٧ فبراير ٢٠٢٤

Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 1: General requirements

ملفات الوثيقة ISO 12417-1:2024

الإنجليزية 48 صفحات
الإصدار الحالي
73.74 BHD

مجال الوثيقة ISO 12417-1:2024

This document specifies requirements for vascular device-drug combination products (VDDCPs).

With regard to safety, this document outlines requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer.

For implanted products, this document is intended to be used as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. This document is intended to be used as a supplement to relevant device-specific standards, such as the ISO 25539 series specifying requirements for endovascular devices. Requirements listed in this document also address VDDCPs that are not permanent implants.

NOTE 1        Due to variations in the design of combination products covered by this document and due to the relatively recent development of some of these combination products, acceptable standardized in vitro test results and clinical study results are not always available. As further scientific and clinical data become available, appropriate revision of this document can be necessary.

This document applies to delivery systems or parts of the delivery system that are an integral component of the vascular device and that are drug-covered (e.g. drug-covered balloon catheters and drug-covered guidewires).

This document does not apply to devices whose PMOA provide a conduit for delivery of a drug (e.g. infusion catheters), unless they contain a drug component that is intended to have an ancillary action to the device part (e.g. antimicrobial coated infusion catheter).

This document does not apply to procedures and devices used prior to and following the introduction of the VDDCP (e.g. balloon angioplasty devices) that do not affect the drug-related aspects of the device.

This document does not provide a comprehensive pharmacological evaluation of VDDCPs.

NOTE 2        Some information about the requirements of certain national and regional authorities is given in Annex B.

The connection of absorbable components of VDDCPs (e.g. coatings) with drug-related aspects of the device are addressed in this document. This document does not provide an exhaustive list of the degradation and other time-dependent aspects of absorbable implants and coatings.

NOTE 3        For more information on absorbable coatings, refer to ISO/TS 17137 and ASTM F3036-13.

This document does not address issues associated with viable or non-viable biological materials such as tissues, cells or proteins.

This document does not address issues associated with active surgical implants (i.e. implants that require power not generated by the human body or gravity).

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
BH GSO 150-2:2015
GSO 150-2:2013 
مواصفة قياسية بحرينية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
BH GSO 2055-1:2016
GSO 2055-1:2015 
لائحة فنية بحرينية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال
GSO 2055-1:2015
 
لائحة فنية خليجية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

ISO/TS 21192:2024
 
مواصفة قياسية دولية
Electronic fee collection — Support for traffic management
ISO 24664:2024
 
مواصفة قياسية دولية
Refrigerating systems and heat pumps — Pressure relief devices and their associated piping — Methods for calculation
ISO/TR 13086-4:2024
 
مواصفة قياسية دولية
Gas cylinders — Guidance for design of composite cylinders — Part 4: Cyclic fatigue of fibres and liners
ISO/TS 21193:2024
 
مواصفة قياسية دولية
Electronic fee collection — Requirements for EFC application interfaces on common media