BH GSO ISO 16063-15:2024

ISO 16063-15:2006
Bahraini Standard   Current Edition · Approved on 21 November 2024

Methods for the calibration of vibration and shock transducers- Part 15: Primary angular calibration by laser interferometry

BH GSO ISO 16063-15:2024 Files

BH GSO ISO 16063-15:2024 Scope

This part of ISO 16063 specifies the instrumentation and procedures used for primary angular vibration calibration of angular transducers, i.e. angular accelerometers, angular velocity transducers and rotational angle transducers (with or without amplifier) to obtain the magnitude and the phase shift of the complex sensitivity by steady-state sinusoidal vibration and laser interferometry. The methods specified in this part of ISO 16063 are applicable to measuring instruments (rotational laser vibrometers in particular) and to angular transducers as defined in ISO 2041 for the quantities of rotational angle, angular velocity and angular acceleration. It is applicable to a frequency range from 1 Hz to 1,6 kHz and a dynamic range (amplitude) from 0,1 rad/s2 to 1 000 rad/s2 (frequency-dependent). These ranges are covered with the uncertainty of measurement specified in Clause 3. Calibration frequencies lower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) and angular acceleration amplitudes smaller than 0,1 rad/s2 can be achieved using method 3A or method 3B specified in this part of ISO 16063, in conjunction with an appropriate low-frequency angular vibration generator. Method 1A (cf. Clause 8: fringe-counting, interferometer type A) and method 1B (cf. Clause 8: fringe-counting, interferometer type B) are applicable to the calibration of the magnitude of complex sensitivity in the frequency range of 1 Hz to 800 Hz and under special conditions, at higher frequencies. Method 2A (cf. Clause 9: minimum-point method, interferometer type A) and method 2B (cf. Clause 9: minimum-point method, interferometer type B) can be used for sensitivity magnitude calibration in the frequency range of 800 Hz to 1,6 kHz. Method 3A (cf. Clause 10: sine-approximation method, interferometer type A) and method 3B (cf. Clause 10: sine-approximation method, interferometer type B) can be used for magnitude of sensitivity and phase calibration in the frequency range of 1 Hz to 1,6 kHz. Methods 1A, 1B and 3A, 3B provide for calibrations at fixed angular acceleration amplitudes at various frequencies. Methods 2A and 2B require calibrations at fixed rotational angle amplitudes (angular velocity amplitude and angular acceleration amplitude vary with frequency). NOTE 1 The numbering 1 to 3 of the methods characterizes the handling of the interferometer output signal(s) analogous to ISO 16063-11: number 1 for fringe counting, number 2 for minimum-point detection and number 3 for sineapproximation. Each of these signal handling procedures can be used together with interferometer types A and B specified in this part of ISO 16063. Interferometer type A designates a Michelson or Mach-Zehnder interferometer with retro-reflector(s) located at a radius, R, from the axis of rotation of the angular exciter. This interferometer type is limited to rotational angle amplitudes of 3° maximum. Interferometer type B designates a Michelson or a Mach-Zehnder interferometer using a circular diffraction grating implemented on the lateral surface of the circular measuring table. This interferometer type is not limited as regards the rotational angle amplitude if the diffraction grating covers the whole lateral surface of the disk (i.e. 360°). Usually, the maximum angular vibration is, in this case, limited by the angular vibration exciter. NOTE 2 Though the calibration methods specified in this part of ISO 16063 are applicable to angular transducers (according to definition in ISO 2041) and, in addition, to measuring instrumentation for angular motion quantities, the specifications are given for transducers as calibration objects, for the sake of simplified description. Some specific information for the calibration of rotational laser vibrometers is given in 4.11 and Figure 11.

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
BH GSO OIML R87:2022
OIML R87:2016 
Bahraini Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
BH GSO OIML R79:2022
OIML R79:2015 
Bahraini Standard
Labeling requirements for prepackages

Recently Published from Metrology Sector

GSO OIML R 69:2002
OIML R 69:1985 
Gulf Standard
GLASS CAPILLARY VISCOMETERS FOR THE MEASUREMENT OF KINEMATIC VISCOSITY VERIFICATION METHOD
GSO 266:1994
 
Gulf Standard
Method of verification of weighbridges for road vehicles (Trucks)
GSO 237:1994
 
Gulf Standard
METHODS OF TESTING AND CALIBRATION OF TAXIMETERS
GSO 1647:2002
OIML 115:1995 
Gulf Standard
Methods of testing and verification for Clinical electrical thermometers with maximum device