BH GSO IEC 62271-104:2012

IEC 62271-104:2009
Bahraini Standard   Historical · Approved on 29 July 2012

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR-Part 104 :Alternating current switches for rated voltage of 52 KV and above

BH GSO IEC 62271-104:2012 Files

English null Pages
Historical Reference Language

BH GSO IEC 62271-104:2012 Scope

IEC 62271-104:2009 applies to three-pole alternating current switches for rated voltages 52 kV and above, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application are designed to comply with the following service applications: - carrying rated normal current continuously; - carrying short-circuit currents for a specified time; - switching of mainly active loads; - switching of no-load transformers; - switching of the charging current of unloaded cables, overhead lines or busbars; - switching of closed-loop circuits; - making short-circuit currents. A further object of this standard is to establish requirements for limited-purpose and special- purpose switches used in transmission and distribution systems. Limited-purpose switches shall comply with one or more of the service applications indicated above. Special-purpose switches may comply with one or more of the service applications indicated above and, in addition, shall be suitable for one or more of the following applications: - switching single capacitor banks; - switching back-to-back capacitor banks; - switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer; - applications requiring an increased number of operating cycles; - switching under earth fault conditions in non-effectively earthed neutral systems. This standard cancels and replaces IEC 60265-2:1988. The major changes with respect to IEC 60265-2 are as follows: - alignment with IEC 62271-1 and IEC 62271-100; - requirements for capacitive current switching aligned with those in IEC 62271-100: classes C1 and C2 are introduced. This publication is to be read in conjunction with IEC 62271-1:2007, IEC 62271-100:2008, IEC 62271-102:2001 and IEC 62271-110:2005.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO 31:1984
 
Gulf Standard
METHODS OF TEST FOR PVC-INSULATED CABLES AND CORDS WITH CIRCULAR COPPER CONDUCTORS
GSO 195:1994
 
Gulf Standard
METHODS OF TEST FOR ADHESIVE INSULATING TAPES FOR ELECTRICAL PURPOSES
GSO 723:1997
 
Gulf Standard
Methods of test for telephone sets.
GSO 1842:2007
 
Gulf Standard
METHODS OF TESTING FOR PLUGS AND SOCKET OUTLETS FOR VOLTAGES FROM 127V AND UP TO 250V FOR HOUSEHOLD AND SIMILAR GENERAL USE