BH GSO ISO 10648-1:2016
ISO 10648-1:1997
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Containment enclosures -- Part 1: Design principles
BH GSO ISO 10648-1:2016 Files
English
28 Pages
Current Edition
Reference Language
63.55 BHD
BH GSO ISO 10648-1:2016 Scope
This part of ISO 10648 applies to enclosures or enclosure lines intended to be used for work on:
— radioactive and/or toxic products where containment is required for protection of personnel and environment,
— sensitive products requiring a special atmosphere and/or a sterile medium.
This part of ISO 10648 deals with three types of containment enclosure:
— glove boxes,
— tong boxes, and
— containment enclosures with larger dimensions, used with remote manipulators mounted behind independent shielding.
Some dimensions of the last two types will be given in a subsequent International Standard dealing with the mounting of tongs and manipulators.
The following enclosures have been deliberately excluded from the scope of this part of ISO 10648:
— pressurized vessels,
— ventilated hoods,
— shielded enclosures, manufactured from concrete only, with or without cladding, or from lead only,
— sealed sources,
— transport packaging for radioactive materials,
— enclosures, primary circuits and vessels of nuclear reactors.
This part of ISO 10648 describes the use and principles of design for containment enclosures chosen as reference examples of the three following types:
— plastic enclosures,
— metal-framed enclosures,
— hot-worked metal enclosures.
The last two types can be mounted behind shielding or can have directly attached shielding.
Where standard dimensions are not suitable, other dimensions may be chosen but the containment enclosure shall comply with this part of ISO 10648 in design principles, mounting and assembly .It shall also comply with relevant safety standards and regulations.
Examples of various seals available and the assembly of containment enclosures are shown in annexes A and В. ISO 10648-2 gives the classification of containment enclosures according to their leak tightness and associated checking methods.
Associated equipment will be detailed in future International Standards.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
GSO IEC TS 62915:2024
IEC TS 62915:2023
Gulf Standard
Photovoltaic (PV) modules - Type approval, design and safety qualification - Retesting