BH GSO ISO 28961:2016

ISO 28961:2012
Bahraini Standard   Current Edition · Approved on 08 February 2016

Acoustics - Statistical distribution of hearing thresholds of otologically normal persons in the age range from 18 years to 25 years under free-field listening conditions

BH GSO ISO 28961:2016 Files

English 12 Pages
Current Edition Reference Language
BHD 30.34

BH GSO ISO 28961:2016 Scope

This International Standard provides descriptive statistics, percentiles, of the hearing threshold distribution whose mean is the reference threshold value specified in ISO 226 and ISO 389-7. The mean and percentile thresholds are specified under the following conditions: a) the sound field in the absence of the listener consists of a free progressive plane wave (free field); b) the sound source is directly in front of the listener (frontal incidence); c) the sound signals are pure (sinusoidal) tones; d) the sound pressure level is measured in the absence of the listener at the position where the centre of the listener's head would be; e) listening is binaural; f) the listeners are otologically normal persons within the age range 18 years to 25 years inclusive. NOTE 1 The xth percentile threshold is the value of threshold below which x % of the individual thresholds of population fall. The threshold distributions in this International Standard have been derived from the results of comprehensive statistical analyses. See Annex D. NOTE 2 The applicability of the percentiles and the values of parameters given in this International Standard to diffuse-field listening conditions has not been examined. They are expected to be applicable to the conditions for the frequencies from 20 Hz to 250 Hz where the threshold difference between free-field and diffuse-field listening conditions is zero as specified in ISO 389-7:2005, Table 1. The percentiles are given in numerical form for the preferred frequencies in the one-third-octave series from 20 Hz to 16 000 Hz inclusive, in accordance with ISO 266, and for some intermediate audiometric frequencies. The percentiles are applicable to the assessment of an individual's hearing in relation to the distribution of hearing thresholds under the above conditions. The percentiles can also be used to evaluate the audibility of low-level noise around hearing threshold. NOTE 3 An application example of hearing threshold distribution to noise evaluation can be found in ISO 7779:2010, Annex D.

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
BH GSO OIML R87:2022
OIML R87:2016 
Bahraini Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
BH GSO OIML R79:2022
OIML R79:2015 
Bahraini Standard
Labeling requirements for prepackages

Recently Published from Metrology Sector

GSO ISO 10713:2026
ISO 10713:2025 
Gulf Standard
Jewellery and precious metals — Gold alloy coatings
GSO ISO 23783-2:2026
ISO 23783-2:2022 
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation
GSO ISO 16610-31:2026
ISO 16610-31:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 31: Robust profile filters: Gaussian regression filters