BH GSO IEC 61158-3-2:2016
IEC 61158-3-2:2014
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Industrial communication networks - Fieldbus specifications - Part 3-2: Data-link layer service definition - Type 2 elements
BH GSO IEC 61158-3-2:2016 Files
English
null Pages
Current Edition
Reference Language
BH GSO IEC 61158-3-2:2016 Scope
1.1 General
This part of IEC 61158 provides common elements for basic time-critical messaging
communications between devices in an automation environment. The term “time-critical” is
used to represent the presence of a time-window, within which one or more specified actions
are required to be completed with some defined level of certainty. Failure to complete
specified actions within the time window risks failure of the applications requesting the
actions, with attendant risk to equipment, plant and possibly human life.
This standard defines in an abstract way the externally visible service provided by the Type 2
:fieldbus data-link layer in terms of
;a) the primitive actions and events of the service
b) the parameters associated with each primitive action and event, and the form which they
take; and
.c) the interrelationship between these actions and events, and their valid sequences
:The purpose of this standard is to define the services provided to
• the Type 2 fieldbus application layer at the boundary between the application and data-link
;layers of the fieldbus reference model
• systems management at the boundary between the data-link layer and systems
.management of the fieldbus reference model
Type 2 DL-service provides both a connected and a connectionless subset of those services
.specified in ISO/IEC 8886
1.2 Specifications
The principal objective of this standard is to specify the characteristics of conceptual data-link
layer services suitable for time-critical communications and thus supplement the OSI Basic
Reference Model in guiding the development of data-link protocols for time-critical
communications. A secondary objective is to provide migration paths from previously-existing
.industrial communications protocols
.This specification may be used as the basis for formal DL-Programming-Interfaces
Nevertheless, it is not a formal programming interface, and any such interface will need to
:address implementation issues not covered by this specification, including
;a) the sizes and octet ordering of various multi-octet service parameters
.b) the correlation of paired request and confirm, or indication and response, primitives
1.3 Conformance
This standard does not specify individual implementations or products, nor does it constrain
.the implementations of data-link entities within industrial automation systems
.There is no conformance of equipment to this data-link layer service definition standard
Instead, conformance is achieved through implementation of the corresponding data-link
.protocol that fulfills the Type 1 data-link layer services defined in this standard
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61076-2-116:2024
IEC 61076-2-116:2022
Gulf Standard
Connectors for electrical and electronic equipment - Product requirements - Part 2 -116: Detail specification for circular connectors size 15 with up to 3+PE power contacts and auxiliary contacts, with bayonet-locking.
GSO IEC 61076-2-115:2024
IEC 61076-2-115:2023
Gulf Standard
Connectors for electrical and electronic equipment - Product requirements - Part 2-115: Circular connectors - Detail specification for 12-pole shielded connectors with 2 A rated current and IP65/IP67 metal housing with push-pull locking
GSO IEC 60034-3:2024
IEC 60034-3:2020
Gulf Standard
Rotating electrical machines - Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines and for synchronous compensators