BH GSO IEC 60077-4:2016
IEC 60077-4:2003
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers
BH GSO IEC 60077-4:2016 Files
English
null Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 60077-4:2016 Scope
In addition to the general requirements of IEC 60077-2, this part of IEC 60077 gives rules for
AC circuit-breakers, the main contacts of which are to be connected to AC overhead contact
lines; the nominal voltage of these circuits being in accordance with IEC 60850.
This standard, together with IEC 60077-2, states specifically:
a) the characteristics of the circuit-breakers;
b) the service conditions with which circuit-breakers have to comply with reference to:
– operation and behaviour in normal service,
– operation and behaviour in short-circuit,
– dielectric properties;
c) the tests for confirming the compliance of the components with the characteristics under
the service conditions and the methods to be adopted for these tests;
d) the information to be marked on, or given with the circuit-breaker.
NOTE 1 Circuit-breakers which are dealt with in this standard may be provided with devices for automatic opening under pre-determined conditions other than those of over-current, for example, undervoltage and reversal of power current. This standard does not deal with the verification of operation under such predetermined conditions.
NOTE 2 The incorporation of electronic components or electronic sub-assemblies into electrotechnical components is now common practice.
Although this standard is not applicable to electronic equipment, the presence of electronic components does not provide a reason to exclude such electrotechnical components from the scope. Electronic sub-assemblies included in the circuit-breakers should comply with the relevant standard for electronics (IEC 60571).
NOTE 3 Certain of these rules may, after agreement between user and manufacturer, be used for electrotechnical components installed on vehicles other than rail rolling stock.
This standard does not cover industrial circuit-breakers which have to comply with IEC 60056.
For these, in order to ensure satisfactory operation, this standard should be used to specify
only the particular requirements for rolling stock. In such cases, a specific document should
state the additional requirements with which the industrial circuit-breakers are to comply, for
example:
– either to be adapted (e.g. for control voltage, environmental conditions, etc.);
– or to be installed and used so that they do not have to endure specific rolling stock conditions;
– or to be additionally tested to prove that these components can withstand satisfactorily the rolling stock conditions.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise