BH GSO IEC 60317-39:2016
IEC 60317-39:1992
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Specifications for particular types of winding wires - Part 39: Glass-fibre braided resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 180
BH GSO IEC 60317-39:2016 Files
English
null Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 60317-39:2016 Scope
This part of IEC 317 specifies the requirements of glass-fibre braided, polyester or polyesterimide varnish-treated, bare or enamelled rectangular copper winding wire, temperature index 180.
NOTE - For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
The enamelled wire shall be based on one of the following standards and shall be agreed between purchaser and supplier.
IEC 317-16: 1990, Specifications for particular types of winding wires - Part 16: Polyester enamelled rectangular copper wire, class 155.
IEC 317-28: 1990, Specifications for particular types of winding wires - Pa rt 28: Polyesterimide enamelled rectangular copper wire, class 180.
IEC 317-29: 1990, Specifications for particular types of winding wires - Part 29: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 200.
IEC 317-30: 1990, Specifications for particular types of winding wires - Part 30: Polyimide enamelled rectangular copper wire, class 220.
When an enamelled wire is used, it must have a minimum class of 155.
The temperature index of the glass-fibre braided varnish-treated wire is dependent upon the type of varnish used. The varnish applied to the glass-fibre is based upon polyester or polyesterimide resin and shall have a minimum temperature index of 180. The method of test is to be agreed between purchaser and supplier. The maximum service temperature shall be determined by experience.
The covering shall consist of a single braid of glass-fibre in two grades of thickness:
- grade G1 and grade G2 or bare covered wires;
- grade 1G1 and grade 1G2 or grade 1 enamelled wires, and
- grade 2G1 and grade 2G2 or grade 2 enamelled wires.
- The range of nominal conductor dimensions covered by this pa rt is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
The specified combinations of width and thickness as well as the specified width/thickness
ratio are given in IEC 317-0-5.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise