BH GSO IEC 61308:2016 Scope
This International Standard is applicable to industrial high-frequency dielectric heating
installations used for the purpose of thermal applications such as melting, drying, welding,
insect extermination, and gluing of partially conductive or non-conductive materials such as
plastics, wood, rubber, textiles, glass, ceramic, paper, bamboo or foodstuffs, in both normal and
protective atmospheres, using, for example, inert gases or vacuum.
This standard relates to high-frequency dielectric heating installations with nominal dielectric
heating frequency in the range from 1 MHz to 300 MHz with rated useful output power greater
than 50 W.
The main purpose of this standard is to assist in compliance with the requirements set out in 6.4
of IEC 60519-9 when testing electroheating power sources. It is not primarily intended as a
means of representing a potential high-frequency heating application for the requirement of the
user. Due to the large variety of dielectric heating applications, any output power value obtained
as a result of these tests should not always be taken as representing the power that can be
dissipated in a particular dielectric heating installation, but, in certain instances, the output
power value could be used as an indication of performance.
The power required to heat a charge is dependent, for example, on the type of material heated,
the temperature of heating and ambient moisture and on the construction of the electrode
system.
NOTE Heating a charge with dielectric parameters deeply changing in time and/or temperature the value of the
output power obtained with the actual charge may be different from that obtained in standard test conditions.
For equipment working outside the ITU-designated bands, the frequency of the generator follows the resonant
frequency of the output circuit, thus the output power can remain fairly stable during the work cycle, even with hand
tuning of the output circuit. Therefore, according to this standard, the test well represents the actual output power in
practical work conditions.
For equipment working in ITU-designated bands, the frequency of the generator remains stable, but the resonant
frequency of the output circuit varies with the change of dielectric parameters of the load. Therefore, the value of the
mean output power in the work cycle can be much lower than the value obtained in the test conditions. This value
depends on the time response of the eventual automatic tuning system.
This standard relates to equipment normally operating under continuous rated conditions.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise