BH GSO IEC 61338-1-4:2016
IEC 61338-1-4:2005
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Waveguide type dielectric resonators - Part 1-4: General information and test conditions - Measurement method of complex relative permittivity for dielectric resonator materials at millimetre-wave frequency
BH GSO IEC 61338-1-4:2016 Files
English
null Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 61338-1-4:2016 Scope
This part of IEC 61338 describes the measurement method of dielectric properties for dielectric resonator materials at millimetre-wave frequency. This standard consists of two measurement methods: a) the dielectric rod resonator method excited by NRD-guide (Non-Radiative Dielectric waveguide) and b) the cut-off waveguide method excited by coaxial cables with small loops. a) The dielectric rod resonator method excited by NRD-guide is similar to the dielectric rod resonator method given in IEC 61338-1-3. This method has the following characteristics: – a complete and exact mathematical solution of complex permittivity is given by computer software; – the measurement error is less than 0,3 % for ε′ and less than 0,05 ×10–4 for tan δ; – the applicable measuring ranges of complex permittivity for this method are as follows: frequency: 30 GHz < f < 100 GHz; relative permittivity: 2 < ε′ < 30; loss factor: 10–6 < tan δ < 10–2. b) The cut-off waveguide method excited by coaxial cables with small loops uses a dielectric plate sample placed in a circular cylinder of the TE011 mode. This method has the following characteristics: – fringe effect is corrected using the correction charts on the basis of rigorous analysis; – the measurement error is less than 0,5 % for ε ' and less than 0,05 ×10–4 for tan δ; – the TCF is measured with high accuracy; – the applicable measuring ranges of dielectric properties for this method are as follows: frequency: 30 GHz < f < 100 GHz; relative permittivity: 2 < ε′ < 30; loss factor: 10–6 < tan δ < 10–2.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines

Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS

GSO IEC 63027:2024
IEC 63027:2023
Gulf Standard
Photovoltaic power systems - DC arc detection and interruption


GSO IEC 60885-3:2024
IEC 60885-3:2015
Gulf Standard
Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables


GSO IEC TS 62257-9-2:2024
IEC TS 62257-9-2:2016
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 9-2: Integrated systems - Microgrids