BH GSO IEC/TR 61352:2016
IEC TR 61352:2006
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Mnemonics and symbols for integrated circuits
BH GSO IEC/TR 61352:2016 Files
English
48 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC/TR 61352:2016 Scope
This Technical Report gives recommendations, mainly to designers and manufacturers of integrated circuits, in order to arrive at symbols for devices with a consistent use of mnemonics and qualifying symbols. It is intended to serve two purposes, namely:
– for white-box symbols, it gives a review of standardized designations;
– for gray-box symbols, it is intended to limit the range of possible variations.
White-box symbols are symbols in which the functional behaviour of an element is fully described by standardized means; the relevant rules and explanations are to be found in IEC 60617 in the application notes associated with the symbols S01463 … S01730 (A00269 … A00315) for binary logic elements, and with the symbols S01748 … S01806 (A00281, A00296, A00321 … A00330) for analogue elements.
Gray-box symbols are symbols in which the functional behaviour of an element, mostly because of its complexity, is (partly) described by other means than those used for white-box symbols, particularly by referring to supporting documentation; the relevant rules and explanations are to be found in IEC 60617 in the application notes associated with the symbols S01731 … S01747 (A00317 … A00319).
Where in the following tables the letter W is shown in the second column, this means that the designation concerned may be used in white-box symbols, as well as in gray-box symbols. A letter G in the second column means that the designation concerned may only be used in graybox symbols, or in white-box symbols between square brackets (e.g. [PDN] as additional information for “power down”). In these tables, the English descriptions appear in the third column and the French in the fourth, because in many cases designations are derived from terms in English. Where the letter m is used, it shall be replaced by the relevant value, identifying number, cycle length, number of bits or sequential number, as each case demands (with the exception of Am for gain adjust). Where m1 × m2 is shown, m1 shall be replaced by the number of words and m2 by the number of bits per word. See symbols S01706 … S01722.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 60287-1-3:2025
IEC 60287-1-3:2023
Gulf Standard
Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses
GSO IEC TS 63042-302:2025
IEC TS 63042-302:2021
Gulf Standard
UHV AC transmission systems - Part 302: Commissioning
GSO IEC 61347-2-8:2025
IEC 61347-2-8:2024
Gulf Standard
Controlgear for electric light sources - Safety - Part 2-8: Particular requirements - Ballasts for fluorescent lamps
GSO IEC 60691:2025
IEC 60691:2023
Gulf Standard
Thermal-links - Requirements and application guide