BH GSO IEC 61582:2016
IEC 61582:2004
Bahraini Standard
Current Edition
·
Approved on
10 February 2016
Radiation protection instrumentation - In vivo counters - Classification, general requirements and test procedures for portable, transportable and installed equipment
BH GSO IEC 61582:2016 Files
English
null Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 61582:2016 Scope
This International Standard specifies the classification, general design requirements, performance characteristics and test procedures for in vivo counting systems for detecting trace amounts of radionuclides in the bodies of persons working in nuclear power plants, laboratories and facilities handling radionuclides, and inhabitants living on territory which may be contaminated by either naturally occurring or artificial radionuclides. The purpose is to determine the dose equivalent to organs and the effective dose of internal radiation for the whole body. This standard is applicable both to equipment with spectroscopic capabilities and instruments for rapid screening for gross internal contamination only. This standard is applicable to instruments for the monitoring of certain critical organs (for example, lungs, thyroid gland, etc.) as well as instruments for monitoring the whole body. The standard applies to equipment for the measurement of the activity of gamma-emitting radionuclides in humans in order to determine the committed dose equivalent due to internal contamination in accordance with the recommendations of the ICRP 60 and ICRP 61. The requirements of the standard are applicable to the installed apparatus, to vehiclemounted equipment and to portable instruments. However, Annex B defines the additional mechanical and environmental performance requirements and the additional testing required for transportable and portable assemblies. The general and radiological requirements of all types of in vivo counters are included in this standard. Depending on the type of instrument and the organ to be checked, measurement geometry may require the subject of the monitoring procedure to stand, sit, or lie. The detection assembly includes one or more radiation detector. Normally, these are shielded-scintillation or semi-conductor detectors. Where identification of the location of contamination is required, the detectors may be collimated. The measurement assembly includes functional units for the processing of signals from the detection assembly as well as units for the display of the measured activity. For the measurement of body mass a built-in weighing machine may be used.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise