BH GSO IEC 62885-2:2022

IEC 62885-2:2016
Bahraini Standard   Current Edition · Approved on 28 April 2022

Surface cleaning appliances - Part 2: Dry vacuum cleaners for household or similar use - Methods for measuring the performance

BH GSO IEC 62885-2:2022 Files

BH GSO IEC 62885-2:2022 Scope

IEC 62885-2:2016 is applicable for measurements of the performance of dry vacuum cleaners for household use in or under conditions similar to those in households. The purpose of this standard is to specify essential performance characteristics of dry vacuum cleaners which are of interest to users and to describe methods for measuring these characteristics. This standard is not intended for cordless vacuum cleaners. For safety requirements, reference is made to IEC 60335-1 and IEC 60335-2-2. This first edition of IEC 62885-2 cancels and replaces IEC 60312-1:2010 and Amendment 1:2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60312-1:2010+AMD1:2011.
a) New terms and definitions have been added in Clause 3.
b) Subclauses 4.2 and 4.6 have been improved for better understanding.
c) Subclause 4.10 has been reviewed and renamed "Carpets for testing".
d) Subclause 5.1.6 has been improved.
e) Figure 1 in 5.4.1 has been improved.
f) Subclause 5.5.3.3 has been improved.
g) Subclauses of 5.7 have been renumbered.
h) Subclause 5.7.3, previously 5.7.2, has been improved.
i) Subclause 5.8.2 has been improved and renamed.
j) The test method in 5.9.2.3 has been updated.
k) A new subclause 5.10 on total emissions while vacuum cleaning has been included.
l) The method in 5.11.6 has been improved.
m) Subclause 6.10 has been renamed "Ability to maintain air flow performance".
n) Subclauses of 6.16 have been renumbered.
o) Subclause 6.16.2, previously 6.16.1, has been improved.
p) New subclauses 6.16.3.5, 6.16.3.6 and 6.16.3.7 have been added.
q) New subclauses 6.17 on operational motor life-time test and 6.18 on rated input power have been added.
r) A new paragraph has been added in 7.2.1.5.
s) In 7.3.2, the insert has been changed to aluminium.
t) A new subclause 7.3.14 on total emissions test has been added.
u) New Annexes D and E have been added.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020 
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023 
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
GSO IEC TS 62915:2024
IEC TS 62915:2023 
Gulf Standard
Photovoltaic (PV) modules - Type approval, design and safety qualification - Retesting