BH GSO IEC 61439-4:2022

IEC 61439-4:2012
Bahraini Standard   Current Edition · Approved on 28 April 2022

Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)

BH GSO IEC 61439-4:2022 Files

English 58 Pages
Current Edition Reference Language

BH GSO IEC 61439-4:2022 Scope

IEC 61439-4:2012 defines the specific requirements of ACS as follows:
- ASSEMBLIES for which the rated voltage does not exceed 1 000 V in case of a.c. or 1 500 V in case of d.c.;
- ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above;
- ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out;
- transportable (semi-fixed) or mobile ASSEMBLIES with enclosure. The manufacture and/or assembly may be carried out other than by the original manufacturer. This first edition of IEC 61439-4 cancels and replaces the second edition of IEC 60439-4 (2004), and constitutes a technical revision. This edition includes the following significant technical changes with respect to the last edition of IEC 60439-4:
- modification of the title as "Part 4: Particular requirements for assemblies for construction sites (ACS)";
- alignment on IEC 61439-1 regarding the structure and technical content, as applicable;
- to allow comparison with tested ACS.

This publication is to be read in conjunction with IEC 61439-1:2011.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 60352-2:2025
IEC 60352-2:2024 
Gulf Standard
Solderless connections - Part 2: Crimped connections - General requirements, test methods and practical guidance
GSO IEC 62973-3:2025
IEC 62973-3:2024 
Gulf Standard
Railway applications - Rolling stock - Batteries for auxiliary power supply systems - Part 3: Lead acid batteries
GSO IEC 62933-5-3:2025
IEC 62933-5-3:2023 
Gulf Standard
Electrical energy storage (EES) systems - Part 5-3: Safety requirements for grid-integrated EES systems – Performing unplanned modification of electrochemical based system
GSO IEC 60669-2-2:2025
IEC 60669-2-2:2024 
Gulf Standard
Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote-control switches (RCS)