BH GSO ASTM F3306:2023
ASTM F3306:19
Bahraini Standard
Current Edition
·
Approved on
05 April 2023
Standard Test Method for Ion Release Evaluation of Medical Implants
BH GSO ASTM F3306:2023 Files
English
0 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO ASTM F3306:2023 Scope
1.1 This test method assesses metal or other ions released
from single-use, metallic, implantable medical devices, or
components thereof, by exposing the device to solutions
simulating the in-vivo environment and temperature in a
container for a predetermined time frame with regular sampling at adequate intervals. Examples of device types that may
be evaluated by this test method include, but are not limited to:
cardiovascular devices, endovascular devices, and orthopedic
implants. Devices which are to be partially implanted, but in
long-term contact within the body (such as external fixation
devices) may also be evaluated using this method.
1.2 This test method is used to assess devices or device
components, or both, in their final form and finish, as they
would be implanted. For modular implants, consideration
should be given to individual testing of every part.
1.3 This test method covers the selection of specimens,
specimen preparation, test environment, method of exposure,
and method for evaluating the results to characterize ion
release. Because of the variety of configurations and sizes of
implants, a variety of specimen container configurations may
be used.
1.4 This test method is not intended for ions only adsorbed
onto the surface of the samples.
1.5 This test method does not apply to absorbable metallic
implants (for example, magnesium-based stents, bone screws,
etc.) that are intentionally designed to degrade in-vivo.
1.6 This test method does not cover the required subsequent
chemical analysis, for example, by inductively coupled plasma
mass spectrometry (ICP-MS), or the validation of the analytical instrumentation.
1.7 This test method does not cover the influence of
dynamic loading and associated surface damage or wear on ion
release. Ion release may change under dynamic loading conditions and wear. Additional testing may be required, depending on the application and outcome of this test method.
Best Sellers From Health Sector
GSO 2017:2023
Gulf Standard
Personal Care and Baby Wet Wipes
BH GSO 2017:2023
GSO 2017:2023
Bahraini Standard
Personal Care and Baby Wet Wipes
BH GSO 2241:2023
GSO 2241:2023
Bahraini Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
Gulf Standard
Cosmetic Products - Body Cleaners
Recently Published from Health Sector
GSO ISO 24806:2026
ISO 24806:2023
Gulf Standard
Recreational diving services — Requirements for rebreather diver training — Decompression diving to 60 m
GSO ISO 23223:2026
ISO 23223:2025
Gulf Standard
Alpine ski boots with improved walking soles — Interface with alpine ski-bindings — Requirements, test methods and marking
GSO ASTM F2236:2026
ASTM F2236:24
Gulf Standard
Standard Consumer Safety Specification for Soft Infant and Toddler Carriers
GSO ISO 21103:2026
ISO 21103:2014
Gulf Standard
Adventure tourism — Information for participants