BH GSO IEC 60071-1:2023
IEC 60071-1:2019
Bahraini Standard
Current Edition
·
Approved on
10 December 2023
Insulation co-ordination - Part 1: Definitions, principles and rules
BH GSO IEC 60071-1:2023 Files
English
70 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 60071-1:2023 Scope
IEC 60071-1:2019 is available as IEC 60071-1:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60071-1:2019 applies to three-phase AC systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the rated withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standard withstand voltages from which the rated withstand voltages are selected. This document describes that the selected withstand voltages are associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this document. Although the principles of this document also apply to transmission line insulation, the values of their withstand voltages can be different from the standard rated withstand voltages. The apparatus committees are responsible for specifying the rated withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this document.
NOTE In IEC 60071-2, all rules for insulation co‑ordination given in this document are justified in detail, in particular the association of the standard rated withstand voltages with the highest voltage for equipment. When more than one set of standard rated withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set.
The main changes from the previous edition are as follows:
- all references are updated to current IEC standards, and the bibliography is deleted;
- some definitions are clarified in order to avoid overlapping and ensure clear understanding;
- letter symbols are changed and corrected in order to keep the consistency with relevant IEC standards;
- some titles are changed to clarify understanding (see Clauses A.2, A.3 and Annex B).
It has the status of a horizontal standard in accordance with IEC Guide 108.
IEC 60071-1:2019 applies to three-phase AC systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the rated withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standard withstand voltages from which the rated withstand voltages are selected. This document describes that the selected withstand voltages are associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this document. Although the principles of this document also apply to transmission line insulation, the values of their withstand voltages can be different from the standard rated withstand voltages. The apparatus committees are responsible for specifying the rated withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this document.
NOTE In IEC 60071-2, all rules for insulation co‑ordination given in this document are justified in detail, in particular the association of the standard rated withstand voltages with the highest voltage for equipment. When more than one set of standard rated withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set.
The main changes from the previous edition are as follows:
- all references are updated to current IEC standards, and the bibliography is deleted;
- some definitions are clarified in order to avoid overlapping and ensure clear understanding;
- letter symbols are changed and corrected in order to keep the consistency with relevant IEC standards;
- some titles are changed to clarify understanding (see Clauses A.2, A.3 and Annex B).
It has the status of a horizontal standard in accordance with IEC Guide 108.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines

Recently Published from Electrical Sector
GSO 195:1994
Gulf Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES

GSO 31:1984
Gulf Standard
METHODS OF TEST FOR
PVC-INSULATED CABLES AND CORDS
WITH CIRCULAR COPPER CONDUCTORS

GSO 723:1997
Gulf Standard
Methods of test for telephone sets.

GSO 1842:2007
Gulf Standard
METHODS OF TESTING FOR PLUGS AND SOCKET OUTLETS FOR VOLTAGES FROM 127V AND UP TO 250V FOR HOUSEHOLD AND SIMILAR GENERAL USE