BH GSO IEC 60728-11:2024
IEC 60728-11:2023
Bahraini Standard
Current Edition
·
Approved on
14 April 2024
Cable networks for television signals, sound signals and interactive services - Part 11: Safety
BH GSO IEC 60728-11:2024 Files
English
83 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 60728-11:2024 Scope
IEC 60728-11:2023 is available as IEC 60728-11:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60728-11:2023 deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. Additional requirements may be applied, for example, referring to:
- electrical installations of buildings and overhead lines,
- other telecommunication services distribution systems,
- water distribution systems,
- gas distribution systems,
- lightning systems.
This document is intended to provide requirements specifically for the safety of the system, personnel working on it, subscribers and subscriber equipment. It deals only with safety aspects and is not intended to define a standard for the protection of the equipment used in the system. IEC 60728-11:2023 cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) Replacement of references to IEC 60065 and IEC 60950-1 with references to IEC 62368-1.
b) Addition of subclauses 4.4 to 4.6.
c) Revised definition of class I equipment, class II equipment, main earthing terminal, see 3.1.6, 3.1.8 and 3.1.31.
d) Addition of definitions for harm, hazard, ordinary person, instructed person, skilled person, see 3.1.22, 3.1.23, 3.1.39, 3.1.40 and 3.1.41.
e) Additional requirement to provide details on the equipment installed, see 4.1.
f) Additional mechanical, design and construction requirements, see 4.2.2.
g) Changes to the accessible part requirements, see 4.2.3.
h) The current carrying capacity and dielectric strength of components is now obligatory, see 8.1.3.
i) The assessment of the risk of lightning strike is now obligatory, see Figure 10.
j) Extension of remote feeding voltage on subscriber feeder, see Table 1.
IEC 60728-11:2023 deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. Additional requirements may be applied, for example, referring to:
- electrical installations of buildings and overhead lines,
- other telecommunication services distribution systems,
- water distribution systems,
- gas distribution systems,
- lightning systems.
This document is intended to provide requirements specifically for the safety of the system, personnel working on it, subscribers and subscriber equipment. It deals only with safety aspects and is not intended to define a standard for the protection of the equipment used in the system. IEC 60728-11:2023 cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) Replacement of references to IEC 60065 and IEC 60950-1 with references to IEC 62368-1.
b) Addition of subclauses 4.4 to 4.6.
c) Revised definition of class I equipment, class II equipment, main earthing terminal, see 3.1.6, 3.1.8 and 3.1.31.
d) Addition of definitions for harm, hazard, ordinary person, instructed person, skilled person, see 3.1.22, 3.1.23, 3.1.39, 3.1.40 and 3.1.41.
e) Additional requirement to provide details on the equipment installed, see 4.1.
f) Additional mechanical, design and construction requirements, see 4.2.2.
g) Changes to the accessible part requirements, see 4.2.3.
h) The current carrying capacity and dielectric strength of components is now obligatory, see 8.1.3.
i) The assessment of the risk of lightning strike is now obligatory, see Figure 10.
j) Extension of remote feeding voltage on subscriber feeder, see Table 1.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 61010-2-033:2025
IEC 61010-2-033:2023
Gulf Standard
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
GSO IEC 60034-2-3:2025
IEC 60034-2-3:2024
Gulf Standard
Rotating electrical machines - Part 2-3: Specific test methods for determining losses and efficiency of converter-fed AC motors
GSO IEC 60404-12:2025
IEC 60404-12:2023
Gulf Standard
Magnetic materials - Part 12: Methods of test for the assessment of the thermal endurance of surface insulation coatings on electrical steel strip and sheet
GSO ISO 30061:2025
ISO 30061:2007
Gulf Standard
Emergency lighting