BH GSO IEC 61472-2:2024
IEC 61472-2:2021
Bahraini Standard
Current Edition
·
Approved on
21 November 2024
Live working - Minimum approach distances - Part 2: Method of determination of the electrical component distance for AC systems from 1,0 kV to 72,5 kV
BH GSO IEC 61472-2:2024 Files
No files for this standard are available in the store currently.
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 61472-2:2024 Scope
IEC 61472-2:2021 specifies a method for determining the electrical component of the minimum approach distances for live working, for AC systems 1 kV up to and including 72,5 kV. This document addresses system overvoltages and the working air distances between equipment and/or workers at different potentials.
The withstand voltage and minimum approach distances determined by the method described in this document can be used only if the following working conditions prevail:
workers are trained for, and skilled in, working live lines or close to live conductors or equipment;
the operating conditions are adjusted so that the statistical overvoltage does not exceed the value selected for the determination of the required withstand voltage;
transient overvoltages are the determining overvoltages;
tool insulation has no continuous film of moisture present on the surface;
no lightning is observed within 10 km of the work site;
allowance is made for the effect of the conducting components of tools.
The withstand voltage and minimum approach distances determined by the method described in this document can be used only if the following working conditions prevail:
workers are trained for, and skilled in, working live lines or close to live conductors or equipment;
the operating conditions are adjusted so that the statistical overvoltage does not exceed the value selected for the determination of the required withstand voltage;
transient overvoltages are the determining overvoltages;
tool insulation has no continuous film of moisture present on the surface;
no lightning is observed within 10 km of the work site;
allowance is made for the effect of the conducting components of tools.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines

Recently Published from Electrical Sector
GSO 195:1994
Gulf Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES

GSO 31:1984
Gulf Standard
METHODS OF TEST FOR
PVC-INSULATED CABLES AND CORDS
WITH CIRCULAR COPPER CONDUCTORS

GSO 723:1997
Gulf Standard
Methods of test for telephone sets.

GSO 1842:2007
Gulf Standard
METHODS OF TESTING FOR PLUGS AND SOCKET OUTLETS FOR VOLTAGES FROM 127V AND UP TO 250V FOR HOUSEHOLD AND SIMILAR GENERAL USE