GSO ISO 9847:2010 Scope
1.1 This International Standard specifies two preferred
methods for the calibration of field pyranometers
using reference pyranometers.
1.2 One method, the outdoor calibration or type I,
employs solar radiation as the Source, while the
other method, the indoor calibration or type II, employs
an artificial radiation Source.
1.2.1 The outdoor calibration of field pyranometers
may be performed with the pyranometer in a horizontal
position (i.e. Zero tilt) (type Ia), in a tilted
Position (type Ib), or at normal incidence (type Ic)
maintaining the receiver surface perpendicular to
the sun’s beam component.
1.2.2 The indoor calibration of field pyranometers
may be performed using an integrating sphere with
shaded (type Ha) or unshaded (type Hb) lamp(s), or
at normal incidence (type HC) frequently using an
Optical bench to present the receiver surface perpendicular
to the beam of the lamp.
Types lla and llb correspond to an outdoor calibration
under conditions of overcast and sunny sky
with large light cloud fields, respectively. Type Ilc is
comparable with the normal incidence calibration
of type lc.
1.3 The methods of calibration specified are
traceable to the worid radiometric reference (WRR);
traceability to the international Pyrheliometric Scale
of 1956 is not permitted.
1.4 This International Standard is applicable to
most types of field pyranometers regardless of the
type of radiation receptor employed. In general, all
pyranometers used for lang-term monitoring of incident
solar irradiance may be calibrated by using the
described methods, provided that the reference
pyranorneter has been calibrated at essentially the
Same tilt from horizontal as the tilt employed in the
calibration.
NOTE 1 Pyranometers used for collector tests should
be calibrated using a reference pyrheliometer (see
ISO 9846).
Best Sellers From Metrology Sector
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages


BH GSO OIML R87:2022
OIML R87:2016
Bahraini Standard
Quantity of product in prepackages



GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages


BH GSO OIML R79:2022
OIML R79:2015
Bahraini Standard
Labeling requirements for prepackages



Recently Published from Metrology Sector
GSO ISO 19749:2024
ISO 19749:2021
Gulf Standard
Nanotechnologies
— Measurements of particle size and shape distributions by scanning electron microscopy


GSO ISO 4373:2024
ISO 4373:2022
Gulf Standard
Hydrometry
— Water level measuring devices


GSO ISO 8529-3:2024
ISO 8529-3:2023
Gulf Standard
Neutron reference radiation fields
— Part 3: Calibration of area and personal dosemeters and determination of their response as a function of neutron energy and angle of incidence


GSO ISO 9847:2024
ISO 9847:2023
Gulf Standard
Solar energy
— Calibration of pyranometers by comparison to a reference pyranometer