GSO 2117:2011

Gulf Standard   Current Edition
· Approved on 12 April 2011 · Edition 1

Safety Requirements for Cord Extension Sets

GSO 2117:2011 Files

Arabic 140 Pages
Current Edition Reference Language
35.5 BHD
English 102 Pages
Current Edition
33.0 BHD

GSO 2117:2011 Scope

This Saudi Standard applies to cord extension sets, rewirable and non rewirable, with earthing contact, with a rated voltage of 220 V having a rated current of 13 A or with a rated voltage of 127 V having a rated current of 15 A, intended for household and similar purposes, either indoors or outdoors. NOTE 1 Cord extension sets with earthing can accept plugs of class II equipments. This standard also applies to plugs incorporated in cord sets, to plugs and portable socket-outlets incorporated in cord extension sets and to plugs and socket-outlets which are a component of an appliance, unless otherwise stated in the standard for the relevant appliance. This Standard also applies to cord extension sets which are intended to be used in a cable reel and therefore they become cable reels with a detachable flexible cable. For the combination of the cord extension set and the reel requirements and tests of IEC 61242 have to be fulfilled in addition. This standard does not apply to – cord extension sets with means for reeling; – plugs, socket-outlets and couplers for industrial purposes; – appliance couplers; – plugs, fixed and portable socket-outlets for ELV; NOTE 2 ELV values are specified in IEC 60364-4-41. – fixed socket-outlets, automatic switches, etc. NOTE 3 Socket-outlets with pilot lights are allowed provided that pilot lights comply with the relevant standard, if any. Cord extension sets should be suitable for use at ambient temperatures not normally exceeding +45 °C, but their average over a period of 24h does not exceed +35 °C, with a lower limit of the ambient air temperature of -7 °C. NOTE 4 Socket-outlets complying with this standard are only suitable for incorporation in equipment in such a way and in such a place that it is unlikely that the surrounding temperature exceeds 35 °C. In locations where special conditions prevail, such as in ships, vehicles and the like and in hazardous locations, for example where explosions are liable to occur, special constructions may be required.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 60755-1:2024
IEC 60755-1:2022 
Gulf Standard
General safety requirements for residual current operated protective devices - Part 1: Residual current operated protective devices for DC systems
GSO IEC TR 63227:2024
IEC TR 63227:2020 
Gulf Standard
Lightning and surge voltage protection for photovoltaic (PV) power supply systems
GSO IEC 62788-7-3:2024
IEC 62788-7-3:2022 
Gulf Standard
Measurement procedures for materials used in photovoltaic modules - Part 7-3: Accelerated stress tests - Methods of abrasion of PV module external surfaces
GSO IEC 63044-4:2024
IEC 63044-4:2021 
Gulf Standard
Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 4: General functional safety requirements for products intended to be integrated in HBES and BACS