GSO EN 771-1:2011
EN 771-1:2003
Gulf Standard
Current Edition
·
Approved on
12 October 2011
Specification for masonry units - Part 1: Clay masonry units
GSO EN 771-1:2011 Files
No files are available for this standard right now!
GSO EN 771-1:2011 Scope
This European Standard specifies the characteristics and performance requirements for masonry units manufactured from clay for use in masonry construction (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering). This European Standard is intended to apply to two groups of fired-clay masonry units: a) LD units (see 3.4 and 5.2) comprising: 1) clay masonry units with a gross dry density of less than or equal to 1 000 kg/m3 for use in protected masonry. b) HD units (see 3.5 and 5.3) comprising: 1) all clay masonry units for use in unprotected masonry; 2) clay masonry units with a gross dry density of greater than 1 000 kg/m3 for use in protected masonry. This European Standard includes those clay masonry units of an overall non-rectangular parallelepiped shape. It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards. It provides for the evaluation of conformity of the product to this European Standard. The marking requirement for products covered by this European Standard is included. This European Standard does not specify standard sizes for clay masonry units, nor does it specify standard work dimensions, angles and radii of specially shaped clay masonry units. This document does not include method of measurement, tolerance and range requirements for dimensions, angles and radii characteristics of specially shaped clay masonry units. This European Standard does not cover requirements for the following: units for paving, flue liners and storey height clay masonry units and clay masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does, however, include clay masonry units for external chimney masonry.
Best Sellers From Construction and Building Sector
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 2084:2010
Gulf Standard
Design and application of speed control humps
BH GSO 440:2024
GSO 440:2007
Bahraini Standard
Calcium Silicate bricks
Recently Published from Construction and Building Sector
GSO ASTM B101:2024
ASTM B101:22
Gulf Standard
Standard Specification for Lead-Coated Copper Sheet and Strip for Building Construction
GSO BS 4868:2024
BS 4868:1972
Gulf Standard
Specification for profiled aluminium sheet for building
GSO ASTM C1224:2024
ASTM C1224:22
Gulf Standard
Standard Specification for Reflective Insulation for Building Applications
GSO ASTM E631:2024
ASTM E631:15(2024)
Gulf Standard
Standard Terminology of Building Constructions