GSO IEC 62209-2:2013
IEC 62209-2:2010
Gulf Standard
Current Edition
·
Approved on
09 September 2013
Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
GSO IEC 62209-2:2013 Files
English
231 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 62209-2:2013 Scope
This part of IEC 62209 series is applicable to any wireless communication device capable of
transmitting electromagnetic fields (EMF) intended to be used at a position near the human
body, in the manner described by the manufacturer, with the radiating part(s) of the device at
distances up to and including 200 mm from a human body, i.e. when held in the hand or in
front of the face, mounted on the body, combined with other transmitting or non-transmitting
devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in
garments. For transmitters used in close proximity to the human ear, the procedures of
IEC 62209-1:2005 are applicable.
This standard is applicable for radio frequency exposure in the frequency range of 30 MHz to
6 GHz, and may be used to measure simultaneous exposures from multiple radio sources
used in close proximity to human body. Definitions and evaluation procedures are provided for
the following general categories of device types: body-mounted, body-supported, desktop,
front-of-face, hand-held, laptop, limb-mounted, multi-band, push-to-talk, clothing-integrated.
The types of devices considered include but are not limited to mobile telephones, cordless
microphones, auxiliary broadcast devices and radio transmitters in personal computers.
This International Standard gives guidelines for a reproducible and conservative
measurement methodology for determining the compliance of wireless devices with the SAR
limits.
Because studies suggest that exclusion of features to represent a hand in human models
constitutes a conservative case scenario for SAR in the trunk and the head, a representation
of a hand is not included if the device is intended to be used next to the head or supported on
or near the torso [73], [80]. This standard does not apply for exposures from transmitting or
non-transmitting implanted medical devices. This standard does not apply for exposure from
devices at distances greater than 200 mm away from the human body.
IEC 62209-2 makes cross-reference to IEC 62209-1:2005 where complete clauses or
subclauses apply, along with any changes specified.
Best Sellers From Metrology Sector
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages


BH GSO OIML R87:2022
OIML R87:2016
Bahraini Standard
Quantity of product in prepackages



GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages


BH GSO OIML R79:2022
OIML R79:2015
Bahraini Standard
Labeling requirements for prepackages



Recently Published from Metrology Sector
GSO OIML R 69:2002
OIML R 69:1985
Gulf Standard
GLASS CAPILLARY VISCOMETERS FOR THE
MEASUREMENT OF KINEMATIC VISCOSITY
VERIFICATION METHOD


GSO 266:1994
Gulf Standard
Method of verification of weighbridges for road vehicles (Trucks)

GSO 237:1994
Gulf Standard
METHODS OF TESTING
AND CALIBRATION OF TAXIMETERS

GSO 1647:2002
OIML 115:1995
Gulf Standard
Methods of testing and verification for Clinical electrical thermometers with maximum device