GSO IEC 60255-121:2017

IEC 60255-121:2014
Gulf Standard   Current Edition · Approved on 03 October 2017

Measuring relays and protection equipment - Part 121: Functional requirements for distance protection

GSO IEC 60255-121:2017 Files

GSO IEC 60255-121:2017 Scope

This part of IEC 60255 specifies minimum requirements for functional and performance evaluation of distance protection function typically used in, but not limited to, line applications for effectively earthed, three-phase power systems. This standard also defines how to document and publish performance tests. This standard covers distance protection function whose operating characteristic can be defined on an impedance plane and includes specification of the protection function, measurement characteristics, phase selection, directionality, starting and time delay characteristics. The test methodologies for verifying performance characteristics and accuracy are included in this standard. The standard defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. It also includes the instrument transformer requirements for the protection function. The distance protection functions covered by this standard are as follows: This standard does not specify the functional description of additional features often associated with digital distance relays such as power swing blocking (PSB), out of step tripping (OST), voltage transformer (VT) supervision, switch onto fault (SOTF), trip on reclose (TOR), the logic for cross country faults in not effectively earthed networks, and trip conversion logic. Only their influence on the distance protection function is covered in this standard. The protection of series-compensated lines is beyond the scope of this standard. The general requirements for measuring relays and protection equipment are defined in IEC 60255-1.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020 
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023 
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
GSO IEC TS 62915:2024
IEC TS 62915:2023 
Gulf Standard