GSO IEC 62703:2017

IEC 62703:2013
Gulf Standard   Current Edition · Approved on 03 October 2017

Expression of performance of fluorometric oxygen analyzers in liquid media

GSO IEC 62703:2017 Files

English 85 Pages
Current Edition Reference Language

GSO IEC 62703:2017 Scope

This International Standard is applicable to fluorometric oxygen analyzers used for the continuous determination of dissolved oxygen partial pressure or concentration. It applies to fluorometric oxygen analyzers suitable for use in water containing liquids, ultrapure waters, fresh or potable water, sea water or other aqueous solutions, industrial or municipal waste water from water bodies (e.g. lakes, rivers, estuaries) as well as for industrial process streams and process liquids. Whilst in principle fluorometric oxygen-analyzers are applicable in gaseous phases, the expression of performance in the gas-phase will not be subject of this standard. The sensor unit of a fluorometric oxygen analyzer being in contact with the media to be measured contains a luminophore in a polymer-membrane permeable for oxygen or within other oxygen permeable materials (or substrates). This standard specifies the terminology, definitions, requirements for statements by manufacturers and tests for fluorometric oxygen analyzers. This standard is in accordance with the general principles set out in IEC 60359 and IEC 60770 series. This standard is applicable to analyzers specified for permanent installation installation in any location (indoors or outdoors) utilizing an on-line measurement technique. Safety requirements are dealt with in IEC 61010-1. Standard range of analogue d.c. current signals used in process control systems are dealt with in IEC 60381-1. Specifications for values for the testing of influence quantities can be found in IEC 60654 series. Requirements for documentation to be supplied with instruments are dealt with in IEC 61187. Requirements for general principles concerning quantities, units and symbols are dealt with in ISO 80000-1:2009. The object of IEC 62703 is: – to specify the general aspects in the terminology and definitions related to the performance of fluorometric oxygen analyzers used for the continuous determination of dissolved oxygen partial pressure or concentration in liquid media; – to unify methods used in making and verifying statements on the functional performance of such analyzers; – to specify which tests should be performed in order to determine the functional performance and how such tests should be carried out; – to provide basic documents to support the application of standards of quality assurance within ISO 9001.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO 2693:2026
 
Gulf Technical Regulation
The GCC Terrestrial Radio Receiver Specifications for AM/FM/T-DAB+
GSO IEC 62841-2-9:2026
IEC 62841-2-9:2015 
Gulf Standard
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 2-9: Particular requirements for hand-held tappers and threaders
GSO EN 54-17:2026
EN 54-17:2005 
Gulf Standard
Fire detection and fire alarm systems - Part 17: Short-circuit isolators
GSO IEC TS 63542:2026
IEC TS 63542:2024 
Gulf Standard
Refrigerant detection systems for flammable refrigerants