GSO IEC 60071-1:2023
IEC 60071-1:2019
Gulf Standard
Current Edition
·
Approved on
10 September 2023
Insulation co-ordination - Part 1: Definitions, principles and rules
GSO IEC 60071-1:2023 Files
No files are available for this standard right now!
GSO IEC 60071-1:2023 Scope
IEC 60071-1:2019 is available as IEC 60071-1:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60071-1:2019 applies to three-phase AC systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the rated withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standard withstand voltages from which the rated withstand voltages are selected. This document describes that the selected withstand voltages are associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this document. Although the principles of this document also apply to transmission line insulation, the values of their withstand voltages can be different from the standard rated withstand voltages. The apparatus committees are responsible for specifying the rated withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this document.
NOTE In IEC 60071-2, all rules for insulation co‑ordination given in this document are justified in detail, in particular the association of the standard rated withstand voltages with the highest voltage for equipment. When more than one set of standard rated withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set.
The main changes from the previous edition are as follows:
- all references are updated to current IEC standards, and the bibliography is deleted;
- some definitions are clarified in order to avoid overlapping and ensure clear understanding;
- letter symbols are changed and corrected in order to keep the consistency with relevant IEC standards;
- some titles are changed to clarify understanding (see Clauses A.2, A.3 and Annex B).
It has the status of a horizontal standard in accordance with IEC Guide 108.
IEC 60071-1:2019 applies to three-phase AC systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the rated withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standard withstand voltages from which the rated withstand voltages are selected. This document describes that the selected withstand voltages are associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this document. Although the principles of this document also apply to transmission line insulation, the values of their withstand voltages can be different from the standard rated withstand voltages. The apparatus committees are responsible for specifying the rated withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this document.
NOTE In IEC 60071-2, all rules for insulation co‑ordination given in this document are justified in detail, in particular the association of the standard rated withstand voltages with the highest voltage for equipment. When more than one set of standard rated withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set.
The main changes from the previous edition are as follows:
- all references are updated to current IEC standards, and the bibliography is deleted;
- some definitions are clarified in order to avoid overlapping and ensure clear understanding;
- letter symbols are changed and corrected in order to keep the consistency with relevant IEC standards;
- some titles are changed to clarify understanding (see Clauses A.2, A.3 and Annex B).
It has the status of a horizontal standard in accordance with IEC Guide 108.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
GSO IEC TS 62915:2024
IEC TS 62915:2023
Gulf Standard
Photovoltaic (PV) modules - Type approval, design and safety qualification - Retesting