GSO IEC 60335-2-29:2024

IEC 60335-2-29:2016
Gulf Standard   Current Edition · Approved on 31 January 2024

Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers

GSO IEC 60335-2-29:2024 Files

GSO IEC 60335-2-29:2024 Scope

IEC 60335-2-29:2016 is available as IEC 60335-2-29:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60335-2-29:2016 deals with the safety of electric battery chargers for household and similar use having an output not exceeding 120 V ripple-free direct current, their rated voltage being not more than 250 V. Battery chargers intended for charging batteries in a household end use application outside the scope of the IEC 60335 series of standards are within the scope of this standard. Requirements for battery chargers for use by children at least 8 years old without supervision are given in Annex AA. Battery chargers not intended for normal household use, but which nevertheless may be a source of danger to the public, such as battery chargers intended for use in garages, shops, light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction; children playing with the appliance. This standard does not apply to built-in:
- battery chargers, except those for installing in caravans and similar vehicles;
- battery chargers that are part of an appliance, the battery of which is not accessible to the user;
- battery chargers intended exclusively for industrial purposes;
- battery chargers intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- battery chargers for emergency lighting or supply units for electronic equipment. This fifth edition cancels and replaces the fourth edition published in 2002 including its Amendment 1 (2004) and its Amendment 2 (2009). It constitutes a technical revision. The principal changes in this edition as compared with the fourth edition of IEC 60335-2-29 are as follows (minor changes are not listed):
- Revised the drop test to refer to IEC 60068-2-31 (21.101);
- Requirements for supply cords on battery chargers used at low temperatures (25.7);
- Requirements for battery chargers having an output voltage exceeding SELV have been added (1, 3.2.2, 3.4.3, 10.101, 24.4, 25.5, 25.7, 25.8, 25.15. 26.5);
- A classification for battery chargers used outdoors has been added (6.2, 29.2) and some notes in Clause 1, Subclauses 7.1 and 22.102, Figure 101 and Annex AA 11.8 have been converted to normative text. It was established on the basis of the fifth edition (2010) of that standard. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication. Key words: Battery, Battery Charger

This publication is to be read in conjunction with IEC 60335-1:2010.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007 
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines

Recently Published from Electrical Sector

GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020 
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023 
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
GSO IEC TS 62915:2024
IEC TS 62915:2023 
Gulf Standard
Photovoltaic (PV) modules - Type approval, design and safety qualification - Retesting