GSO ASTM D56:2024 Scope
1.1 This test method covers the determination of the flash
point, by Tag manual and automated closed testers, of liquids
with a viscosity below 5.5 mm2
/s (cSt) at 40 °C (104 °F), or
below 9.5 mm2
/s (cSt) at 25 °C (77 °F), and a flash point below
93 °C (200 °F).
1.1.1 Two sets of test conditions are used within this test
method: low temperature (LT) test conditions for expected
flash points < 60 °C, and high temperature (HT) test conditions
for expected flash points of ≥ 60 °C.
1.1.2 For the closed-cup flash point of liquids with the
following properties: a viscosity of 5.5 mm2
/s (cSt) or more at
40 °C (104 °F); a viscosity of 9.5 mm2
/s (cSt) or more at 25 °C
(77 °F); a flash point of 93 °C (200 °F) or higher; a tendency to
form a surface film under test conditions; or containing
suspended solids, Test Method D93 can be used.
1.1.3 For cut-back asphalts refer to Test Methods D1310
and D3143.
NOTE 1—The U.S. Department of Transportation (RSTA)2 and U.S.
Department of Labor (OSHA) have established that liquids with a flash
point under 37.8 °C (100 °F) are flammable as determined by this test
method for those liquids that have a viscosity less than 5.5 mm2
/s (cSt) at
40 °C (104 °F) or 9.5 mm2
/s (cSt) or less at 25 °C (77 °F), or do not
contain suspended solids or do not have a tendency to form a surface film
while under test. Other flash point classifications have been established by
these departments for liquids using this test method.
1.2 This test method can be used to measure and describe
the properties of materials, products, or assemblies in response
to heat and flame under controlled laboratory conditions and
cannot be used to describe or appraise the fire hazard or fire
risk of materials, products, or assemblies under actual fire
conditions. However, results of this test method can be used as
elements of fire risk assessment that takes into account all of
the factors that are pertinent to an assessment of the fire hazard
of a particular end use.
1.3 Related standards are Test Methods D93, D1310,
D3828, D3278, and D3941.
Best Sellers From Oil and Gas Sector
GSO 1180:2021
Gulf Standard
Automatic transmission fluid (ATF)
BH GSO 1180:2022
GSO 1180:2021
Bahraini Standard
Automatic transmission fluid (ATF)
GSO 672:2010
Gulf Standard
Liquefied petroleum gases (LPG) for household use( mixture of commerical propane and butane).
GSO 1161:2021
Gulf Standard
HLP HYDRAULIC OILS
Recently Published from Oil and Gas Sector
GSO ASTM D7164:2024
ASTM D7164:21
Gulf Standard
Standard Practice for On-line/At-line Heating Value Determination of Gaseous Fuels by Gas Chromatography
GSO ISO 4259-3:2024
ISO 4259-3:2020
Gulf Standard
Petroleum and related products
— Precision of measurement methods and results
— Part 3: Monitoring and verification of published precision data in relation to methods of test
GSO ISO 4266-4:2024
ISO 4266-4:2023
Gulf Standard
Petroleum and liquid petroleum products
— Measurement of level and temperature in storage tanks by automatic methods
— Part 4: Measurement of temperature in atmospheric tanks
GSO ASTM D235:2024
ASTM D235:22
Gulf Standard
Standard Specification for Mineral Spirits (Petroleum Spirits) (Hydrocarbon Dry Cleaning Solvent)