GSO ISO 80601-2-69:2024

ISO 80601-2-69:2020
Gulf Standard   Current Edition · Approved on 25 April 2024

Medical electrical equipment — Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment

GSO ISO 80601-2-69:2024 Files

English 62 Pages
Current Edition Reference Language
81.14 BHD

GSO ISO 80601-2-69:2024 Scope

This document specifies requirements for the basic safety and essential performance of an oxygen concentrator in combination with its accessories, hereafter referred to as ME equipment, intended to increase the oxygen concentration of gas intended to be delivered to a single patient. Such oxygen concentrators are typically intended for use in the home healthcare environment by a single patient in various environments including any private and public transportation as well as in commercial aircraft.

NOTE 1 Such oxygen concentrators can also be used in professional healthcare facilities.

This document is applicable to a transit-operable and non-transit-operable oxygen concentrator. This document is applicable to an oxygen concentrator integrated into or used with other medical devices, ME equipment or ME systems.

EXAMPLE 1 An oxygen concentrator with integrated oxygen conserving equipment function or humidifier function.

EXAMPLE 2 An oxygen concentrator used with a flowmeter stand.

EXAMPLE 3 An oxygen concentrator as part of an anaesthetic system for use in areas with limited logistical supplies of electricity and anaesthetic gases[2].

EXAMPLE 4 An oxygen concentrator with an integrated liquid reservoir function or gas cylinder filling system function.

This document is also applicable to those accessories intended by their manufacturer to be connected to an oxygen concentrator, where the characteristics of those accessories can affect the basic safety or essential performance of the oxygen concentrator.

NOTE 2 Such accessories can include, but are not limited to, masks, cannulae, extension tubing, humidifiers, carts, carrying cases, external power sources and oxygen conserving equipment.

This document does not specify requirements for oxygen concentrators for use with a medical gas pipeline system.

If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard.

NOTE 3 See also 4.2 of the general standard.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
BH GSO 2017:2023
GSO 2017:2023 
Bahraini Standard
Personal Care and Baby Wet Wipes
BH GSO 2241:2023
GSO 2241:2023 
Bahraini Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners

Recently Published from Health Sector

GSO ISO 18113-4:2024
ISO 18113-4:2022 
Gulf Standard
In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 4: In vitro diagnostic reagents for self-testing
GSO EN 716-1:2017+AC:2024
EN 716-1:2017+AC:2019 
Gulf Standard
Furniture - Children's cots and folding cots for domestic use - Part 1: Safety requirements
GSO ASTM F2011:2024
ASTM F2011:02(2018) 
Gulf Standard
Standard Specification for Safety and Performance of Fun-Karts
GSO ISO 18113-3:2024
ISO 18113-3:2022 
Gulf Standard
In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 3: In vitro diagnostic instruments for professional use