GSO IEC 62305-2:2025
IEC 62305-2:2024
Gulf Standard
Current Edition
·
Approved on
14 October 2025
Protection against lightning - Part 2: Risk management
GSO IEC 62305-2:2025 Files
English
256 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 62305-2:2025 Scope
IEC 62305-2:2024 is applicable to the risk management of a structure due to lightning flashes to earth.
Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure provides a means for the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit.
This third edition cancels and replaces the second edition, published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The concept of a single risk, to combine loss of human life and loss due to fire, has been introduced.
b) The concept of frequency of damage that can impair the availability of the internal systems within the structure has been introduced.
c) The lightning ground strike-point density NSG has been introduced replacing the lightning flash density NG in the evaluation of expected average annual number of dangerous events.
d) Reduction of a few risk components can be achieved by the use of preventive temporary measures activated by means of a thunderstorm warning system (TWS) compliant with IEC 62793. The risk of direct strike to people in open areas has been introduced, considering the reduction of that risk using a TWS.
The content of the corrigendum 1 (2024-10) has been included in this copy.
Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure provides a means for the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit.
This third edition cancels and replaces the second edition, published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The concept of a single risk, to combine loss of human life and loss due to fire, has been introduced.
b) The concept of frequency of damage that can impair the availability of the internal systems within the structure has been introduced.
c) The lightning ground strike-point density NSG has been introduced replacing the lightning flash density NG in the evaluation of expected average annual number of dangerous events.
d) Reduction of a few risk components can be achieved by the use of preventive temporary measures activated by means of a thunderstorm warning system (TWS) compliant with IEC 62793. The risk of direct strike to people in open areas has been introduced, considering the reduction of that risk using a TWS.
The content of the corrigendum 1 (2024-10) has been included in this copy.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO 2693:2026
Gulf Technical Regulation
The GCC Terrestrial Radio Receiver Specifications for AM/FM/T-DAB+
GSO IEC 60335-2-79:2026
IEC 60335-2-79:2021
Gulf Standard
Household and similar electrical appliances - Safety - Part 2-79: Particular requirements for high pressure cleaners and steam cleaners
GSO IEC TS 63542:2026
IEC TS 63542:2024
Gulf Standard
Refrigerant detection systems for flammable refrigerants
GSO IEC 61557-14:2026
IEC 61557-14:2023
Gulf Standard
Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment of machinery