ISO 11608-1:2022

International Standard   Current Edition · Approved on 07 April 2022

Needle-based injection systems for medical use — Requirements and test methods — Part 1: Needle-based injection systems

ISO 11608-1:2022 Files

English 69 Pages
Current Edition
93.07 BHD

ISO 11608-1:2022 Scope

This document specifies requirements and test methods for Needle-Based Injection Systems (NISs) for single-patient use intended to deliver discrete volumes (bolus) of medicinal product, which can be delivered through needles or soft cannulas for intradermal, subcutaneous and/or intramuscular delivery, incorporating pre-filled or user-filled, replaceable or non-replaceable containers.

This document applies in cases where the NIS incorporates a prefilled syringe. However, stand-alone prefilled syringes defined by ISO 11040-8 are not covered by this document (see exclusions below).

It is important to note that other functions and characteristics of the prefilled syringe, such as dose accuracy, are subject to the requirements (delivered volume) in ISO 11040-8 and not this document, unless the addition impacts the delivery function (e.g. a mechanism that intends to restrict or stop the plunger movement, which would limit the dose delivered). In that case, the system is completely covered by this document and applicable requirements of the ISO 11608 series.

Excluded from the scope are:

—    stand-alone prefilled syringes defined by ISO 11040-8 (with noted exceptions above);

—    NISs that provide continuous delivery and require a delivery rate clinically specified in the medicinal product labelling or determined by a physician based on clinical relevance (i.e. medication efficacy) as would be the case with insulin patch pumps or traditional infusion pumps (e.g. IEC 60601-2-24, ISO 28620) associated with continuous delivery of medicinal products (e.g. insulin);

—    NISs with containers that can be refilled multiple times;

—    requirements relating to methods or equipment associated with user filling of containers unless they are dedicated accessories (a component necessary for primary function, whether included in the original kitted product or not);

—    NISs intended for dental use;

—    NISs intended for different routes of administration (e.g. intravenous, intrathecal, intraocular).

NOTE       These products that are excluded might benefit from elements in this document but might not completely fulfil the basic safety and effectiveness of such products.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 2055-1:2016
GSO 2055-1:2015 
Bahraini Technical Regulation
HALAL FOOD - Part 1 : General Requirements
GSO 2055-1:2015
 
Gulf Technical Regulation
HALAL FOOD - Part 1 : General Requirements

Recently Published

ISO 22552:2025
 
International Standard
Space systems — Manufacturing readiness review
ISO/IEC TR 16088:2025
 
International Standard
Information technology — Computer graphics, image processing and environmental representation — Constructs for visual positioning systems in mixed and augmented reality (MAR)
ISO 18618:2025
 
International Standard
Dentistry — Interoperability of CAD/CAM systems
ISO 10286:2025
 
International Standard
Gas cylinders — Vocabulary