ISO 25539-3:2024

International Standard   Current Edition
· Approved on 17 October 2024 ·

Cardiovascular implants — Endovascular devices — Part 3: Vena cava filters

ISO 25539-3:2024 Files

English 99 Pages
Current Edition
93.83 BHD

ISO 25539-3:2024 Scope

This document specifies the requirements for the evaluation of vena cava filter systems (filters and delivery systems) and the requirements with respect to nomenclature, design attributes and information supplied by the manufacturer. Guidance for the development of in vitro test methods is included in Annex D. This document is intended to be used in conjunction with ISO 14630, which specifies general requirements for the performance of non-active surgical implants.

NOTE 1       Due to the variations in the design of implants covered by this document, and in some cases due to the emergence of novel types of such implants, acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, a revision of this document will be necessary.

This document is applicable to vena cava filters intended to prevent symptomatic pulmonary embolism by capturing blood clots in the inferior vena cava (IVC). While this document can be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address the use of filters in other implantation sites.

This document is also applicable to permanent filters together with their associated delivery systems, optional filters that can be retrieved and their associated retrieval systems, and convertible filters and their associated conversion systems. While this document can be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning.

This document is not applicable to

           temporary filters (e.g. tethered) that need to be removed after a defined period of time,

           issues associated with viable tissues and non-viable biological materials, and

           procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure.

Although absorbable filters and filters with absorbable coatings are within the scope of this document, this document is not comprehensive with respect to the absorbable properties of these devices.

NOTE 2       Absorbable implants are covered in ISO/TS 17137.

Although coated filters and coated filter systems are within the scope of this document, this document is not comprehensive with respect to coatings.

NOTE 3       Vascular device-drug combination products are covered in ISO 12417-1 and some coating properties are covered in ISO 25539-4.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 2055-1:2016
GSO 2055-1:2015 
Bahraini Technical Regulation
HALAL FOOD - Part 1 : General Requirements
GSO 2055-1:2015
 
Gulf Technical Regulation
HALAL FOOD - Part 1 : General Requirements

Recently Published

ISO/IEC 27019:2024
 
International Standard
Information security, cybersecurity and privacy protection — Information security controls for the energy utility industry
ISO/TS 6204:2024
 
International Standard
Health Informatics — Categorial structures for representation of Ayurvedic medicinal water — Decocting process in Ayurveda
ISO 3379:2024
 
International Standard
Leather — Determination of distension and strength of surface (ball burst method)
ISO 19403-4:2024
 
International Standard
Paints and varnishes — Wettability — Part 4: Determination of the polar and dispersive fractions of the surface tension of liquids from an interfacial tension