ISO 15883-1:2024 Scope

This document specifies general performance requirements for washer-disinfectors (WD) and washer-disinfector accessories that are intended to be used for cleaning and disinfection of reusable medical devices. It specifies performance requirements for cleaning and disinfection as well as for the accessories that can be required to achieve the necessary performance. The methods and instrumentation required for validation, routine control and monitoring and requalification, periodically and after essential repairs, are also specified.

NOTE 1        The requirements can be applied to WD intended for use with other articles used in the context of medical, dental, pharmaceutical and veterinary practice.

The requirements for WD intended to process specific loads are specified in ISO 15883-2, ISO 15883-3, ISO 15883-4, ISO 15883-6 and ISO 15883-7. For WD intended to process loads of two or more different types, the requirements of the applicable parts of ISO 15883-2, ISO 15883-3, ISO 15883-4, ISO 15883-6 and ISO 15883-7 apply.

This document does not specify requirements intended for machines for use for laundry or general catering purposes.

This document does not include requirements for machines which are intended to sterilize the load, or which are designated as “sterilizers” and addressed in other standards.

The specified performance requirements of this document do not ensure the inactivation or removal of the causative agent(s) (prion protein) of transmissible spongiform encephalopathies.

NOTE 2        Chemicals in some cleaning agents and disinfectants can react with prion protein in a manner that can inhibit its removal or inactivation.  If the presence of prion protein is considered a possibility, then this can influence the choice of cleaning agent and disinfectant.

NOTE 3        This document can be used by prospective purchasers and manufacturers as the basis of agreement on the specification of a WD. The test methods for demonstration of conformity with the requirements of this document can also be employed by users to demonstrate continued conformity of the installed WD throughout its service life. Guidance on a routine test programme is given in Annex A.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs
BH GSO 9:2023
GSO 9:2022 
Bahraini Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO 22367:2026
 
International Standard
Medical laboratories — Application of risk management to medical laboratories
ISO/IEC 15067-5:2026
 
International Standard
Information technology — Home Electronic System (HES) application model — Part 5: A safety framework and guidelines for control and data communication messages
ISO 25184:2026
 
International Standard
Molecular biomarker analysis — Nucleotide sequencing — Verified next generation sequences (VNGS)
ISO 15548-1:2026
 
International Standard
Non-destructive testing — Equipment for eddy current examination — Part 1: Instrument characteristics and verification