IEC/TS 81001-2-2:2025

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٠٣ أكتوبر ٢٠٢٥

Health software and health IT systems safety, effectiveness and security — Part 2-2: Guidance for the implementation, disclosure and communication of security needs, risks and controls

ملفات الوثيقة IEC/TS 81001-2-2:2025

الإنجليزية 96 صفحات
الإصدار الحالي

مجال الوثيقة IEC/TS 81001-2-2:2025

This document presents an informative set of common, high-level security-related capabilities and additional considerations to be used across the life cycle of health software and health IT systems, for the information exchange between the health software manufacturers (including medical device manufacturers), healthcare delivery organizations (HDOs) and other stakeholders. It is applicable to health software running on any platform and in any environment such as cloud, on premise or hybrid. While important security topics, the following are outside the scope of this document: a) the security policies of the HDO, b) the product and services security policies of the manufacturer, c) determinations of risk tolerance by the HDO or manufacturer, and d) clinical studies where there is a need to secure personal data. As security risks can be caused by any product on health IT systems and health IT Infrastructure, considerations in this document can be applied for other products that are not health software. IEC TS 81001-2-2:2025 withdraws and replaces: – IEC TR 80001-2-2, Application of risk management for IT-networks incorporating medical devices – Part 2-2: Guidance for the communication of medical device security needs, risks and controls – IEC TR 80001-2-8, Application of risk management for IT-networks incorporating medical devices – Part 2-8: Application guidance – Guidance on standards for establishing the security capabilities identified in IEC TR 80001-2-2 This document includes the following significant changes: a) Combines and updates the contents of IEC TR 80001-2-2 and IEC TR 80001-2-8; b) Extends the scope to health software instead to only medical device software; c) Aligns contents and definitions to ISO 81001-1:2021 and the updated IEC 80001-1; d) Removed the Configuration of Security Features (CNFS) capability, as any configurable security capability shall be clearly communicated. e) Provide security control mappings to several new standards, e.g. IEC TR 60601-4-5, IEC 62443-4-2, ISO/IEEE 11073-40102 and the recent versions of previous standards, e.g. ISO/IEC 27002 and NIST 800-53 version 5.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
BH GSO 150-2:2015
GSO 150-2:2013 
مواصفة قياسية بحرينية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 9:2022
 
لائحة فنية خليجية
بطاقات المواد الغذائية المعبأة
BH GSO 9:2023
GSO 9:2022 
لائحة فنية بحرينية
بطاقات المواد الغذائية المعبأة

اعتمدت مؤخراً

ISO 22367:2026
 
مواصفة قياسية دولية
Medical laboratories — Application of risk management to medical laboratories
ISO/IEC 15067-5:2026
 
مواصفة قياسية دولية
Information technology — Home Electronic System (HES) application model — Part 5: A safety framework and guidelines for control and data communication messages
ISO 25184:2026
 
مواصفة قياسية دولية
Molecular biomarker analysis — Nucleotide sequencing — Verified next generation sequences (VNGS)
ISO 15548-1:2026
 
مواصفة قياسية دولية
Non-destructive testing — Equipment for eddy current examination — Part 1: Instrument characteristics and verification