ISO 80601-2-67:2026

International Standard   Current Edition · Approved on 10 April 2026

Medical electrical equipment — Part 2-67: Particular requirements for basic safety and essential performance of oxygen-conserving equipment

ISO 80601-2-67:2026 Files

English 59 Pages
Current Edition
BHD 98.13

ISO 80601-2-67:2026 Scope

This document is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as ME equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home healthcare environment. Oxygen conserving equipment is typically used by a lay operator.

NOTE 1        Conserving equipment can also be used in professional health care facilities.

This document is also applicable to conserving equipment that is incorporated with other equipment.

EXAMPLE            Conserving equipment combined with a pressure regulator[4], an oxygen concentrator[12] or liquid oxygen equipment[7].

This document is also applicable to those accessories intended by their manufacturer to be connected to conserving equipment, where the characteristics of those accessories can affect the basic safety or essential performance of the conserving equipment.

This document is intended to clarify the difference in operation of various conserving equipment models, as well as between the operation of conserving equipment and continuous flow oxygen equipment, by requiring standardized performance testing and labelling.

This document is only applicable to active devices (e.g. pneumatically or electrically powered) and is not applicable to non-active devices (e.g. reservoir cannulas). 

If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.

NOTE 2        Additional information can be found in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs
BH GSO 9:2023
GSO 9:2022 
Bahraini Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO 14505-1:2026
 
International Standard
Ergonomics of the thermal environment — Evaluation of thermal environments in vehicles — Part 1: Principles and methods for assessment of thermal stress
ISO 11228-3:2026
 
International Standard
Ergonomics — Manual handling — Part 3: Repetitive movements and exertions of the upper limbs
ISO 12236:2026
 
International Standard
Geosynthetics — Static puncture test (CBR test)
ISO 12179:2026
 
International Standard
Geometrical product specifications (GPS) — Surface texture: Profile — Calibration of contact (stylus) instruments