ISO 19361:2025

International Standard   Current Edition · Approved on 11 July 2025

Measurement of radioactivity — Determination of beta emitters activities — Test method using liquid scintillation counting

ISO 19361:2025 Files

English 22 Pages
Current Edition
BHD 63.6

ISO 19361:2025 Scope

This document applies to the determination of beta emitters activity concentration using liquid scintillation counting. The method requires the preparation of a scintillation source, which is obtained by mixing the test sample and a scintillation cocktail. The test sample can be liquid (aqueous or organic), or solid (particles or filter or planchet).

NOTE            Planchet are samples, described in 8.5, out of solid material e.g. small metal, plastic or glass pans or support material made of these materials

This document describes the conditions for measuring the activity concentration of beta emitter radionuclides by liquid scintillation counting[2].

The choice of the test method using liquid scintillation counting involves the consideration of the potential presence of other beta-, alpha- and gamma emitter radionuclides in the test sample. In this case, a specific sample treatment by separation or extraction is implemented to isolate the radionuclide of interest in order to avoid any interference with other beta-, alpha- and gamma-emitting radionuclides during the counting phase.

This document is applicable to all types of liquid samples having an activity concentration ranging from about 1 Bq·l−1 to 106 Bq·l−1. For a liquid test sample, it is possible to dilute liquid test samples in order to obtain a solution having an activity compatible with the measuring instrument. For solid samples, the activity of the prepared scintillation source shall be compatible with the measuring instrument.

The measurement range is related to the test method used: nature of test portion, preparation of the scintillator - test portion mixture, measuring assembly as well as to the presence of the co-existing activities due to interfering radionuclides.

Test portion preparations (such as distillation for 3H measurement, or benzene synthesis for 14C measurement, etc.) are outside the scope of this document and are described in specific test methods using liquid scintillation[3][[4][5][6][7][8][9][10].

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs
BH GSO 9:2023
GSO 9:2022 
Bahraini Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO 22367:2026
 
International Standard
Medical laboratories — Application of risk management to medical laboratories
ISO/IEC 15067-5:2026
 
International Standard
Information technology — Home Electronic System (HES) application model — Part 5: A safety framework and guidelines for control and data communication messages
ISO 25184:2026
 
International Standard
Molecular biomarker analysis — Nucleotide sequencing — Verified next generation sequences (VNGS)
ISO 15548-1:2026
 
International Standard
Non-destructive testing — Equipment for eddy current examination — Part 1: Instrument characteristics and verification