BH GSO IEC 62128-2:2016
IEC 62128-2:2013
Bahraini Standard
Current Edition
·
Approved on
08 February 2016
Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 2: Provisions against the effects of stray currents caused by d.c. traction systems
BH GSO IEC 62128-2:2016 Files
English
null Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
BH GSO IEC 62128-2:2016 Scope
This part of IEC 62128 specifies requirements for protective provisions against the effects of stray currents, which result from the operation of d.c. traction systems. As experience for several decades has not shown evident corrosion effects from a.c. traction systems and actual investigations are not completed, this standard only deals with stray currents flowing from a d.c. traction system. This standard applies to all metallic fixed installations which form part of the traction system, and also to any other metallic components located in any position in the earth, which can carry stray currents resulting from the operation of the railway system. This standard applies to all new d.c. lines and to all major revisions to existing d.c. lines. The principles may also be applied to existing electrified transportation systems where it is necessary to consider the effects of stray currents. It provides design requirements to allow maintenance. The range of application includes: a) railways, b) guided mass transport systems such as: 1) tramways, 2) elevated and underground railways, 3) mountain railways, 4) trolleybus systems, and 5) magnetically levitated systems, which use a contact line system, c) material transportation systems. This standard does not apply to: d) mine traction systems in underground mines, e) cranes, transportable platforms and similar transportation equipment on rails, temporary structures (e.g. exhibition structures) in so far as these are not supplied directly from the contact line system and are not endangered by the traction power supply system, f) suspended cable cars, g) funicular railways. This standard does not specify working rules for maintenance.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
BH GSO 34:2015
GSO 34:2007
Bahraini Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
Recently Published from Electrical Sector
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 60884-2-7:2026
IEC 60884-2-7:2025
Gulf Standard
Plugs and socket-outlets for household and similar purposes - Part 2-7: Particular requirements for cord extension sets
GSO IEC 60809:2026
IEC 60809:2021
Gulf Standard
Lamps and light sources for road vehicles - Dimensional, electrical and luminous requirements
GSO IEC TS 62600-100:2026
IEC TS 62600-100:2024
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 100: Electricity producing wave energy converters - Power performance assessment