ISO 22442-1:2015

International Standard   Historical · Approved on 02 November 2015

Medical devices utilizing animal tissues and their derivatives — Part 1: Application of risk management

ISO 22442-1:2015 Files

English 27 Pages
Historical
BHD 74.85

ISO 22442-1:2015 Scope

ISO 22442-1:2015 applies to medical devices other than in vitro diagnostic medical devices manufactured utilizing materials of animal origin, which are non-viable or have been rendered non-viable. It specifies, in conjunction with ISO 14971, a procedure to identify the hazards and hazardous situations associated with such devices, to estimate and evaluate the resulting risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, it outlines the decision process for the residual risk acceptability, taking into account the balance of residual risk, as defined in ISO 14971, and expected medical benefit as compared to available alternatives. This part of ISO 22442 is intended to provide requirements and guidance on risk management related to the hazards typical of medical devices manufactured utilizing animal tissues or derivatives such as

a) contamination by bacteria, moulds or yeasts;

b) contamination by viruses;

c) contamination by agents causing Transmissible Spongiform Encephalopathies (TSE);

d) material responsible for undesired pyrogenic, immunological or toxicological reactions.

For parasites and other unclassified pathogenic entities, similar principles can apply.

ISO 22442-1:2015 does not stipulate levels of acceptability which, because they are determined by a multiplicity of factors, cannot be set down in such an International Standard except for some particular derivatives mentioned in Annex C. Annex C stipulates levels of TSE risk acceptability for tallow derivatives, animal charcoal, milk and milk derivatives, wool derivatives and amino acids.

ISO 22442-1:2015 does not specify a quality management system for the control of all stages of production of medical devices.

ISO 22442-1:2015 does not cover the utilization of human tissues in medical devices.

NOTE 1 It is not a requirement of this part of ISO 22442 to have a full quality management system during manufacture. However, attention is drawn to International Standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices.

NOTE 2 For guidance on the application of this part of ISO 22442, see Annex A.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs
BH GSO 9:2023
GSO 9:2022 
Bahraini Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO 22367:2026
 
International Standard
Medical laboratories — Application of risk management to medical laboratories
ISO/IEC 15067-5:2026
 
International Standard
Information technology — Home Electronic System (HES) application model — Part 5: A safety framework and guidelines for control and data communication messages
ISO 25184:2026
 
International Standard
Molecular biomarker analysis — Nucleotide sequencing — Verified next generation sequences (VNGS)
ISO 15548-1:2026
 
International Standard
Non-destructive testing — Equipment for eddy current examination — Part 1: Instrument characteristics and verification