ISO 52016-3:2023

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٢٩ سبتمبر ٢٠٢٣

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 3: Calculation procedures regarding adaptive building envelope elements

ملفات الوثيقة ISO 52016-3:2023

الإنجليزية 55 صفحات
الإصدار الحالي
BHD 96.46

مجال الوثيقة ISO 52016-3:2023

This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.

The three types of adaptive building envelope elements covered in this document are:

     building envelope elements with dynamic solar shading;

     building envelope elements with chromogenic glazing;

     building envelope elements with an actively ventilated cavity.

Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.

This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.

It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building.

In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.

This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.

NOTE            The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
BH GSO 150-2:2015
GSO 150-2:2013 
مواصفة قياسية بحرينية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
GSO 9:2022
 
لائحة فنية خليجية
بطاقات المواد الغذائية المعبأة
BH GSO 9:2023
GSO 9:2022 
لائحة فنية بحرينية
بطاقات المواد الغذائية المعبأة

اعتمدت مؤخراً

ISO 24131-4:2026
 
مواصفة قياسية دولية
Internal protection by polymeric lining for ductile iron pipes — Requirements and test methods — Part 4: Ceramic epoxy lining
ISO 23611-1:2026
 
مواصفة قياسية دولية
Soil quality — Sampling of soil invertebrates — Part 1: Hand-sorting and extraction of earthworms
ISO 24829:2026
 
مواصفة قياسية دولية
Plastics — Polyether polyols and polymer polyols — Determination of aldehydes and ketones
ISO 12480-5:2026
 
مواصفة قياسية دولية
Cranes — Safe use — Part 5: Bridge and gantry cranes