ISO 52016-3:2023

International Standard   Current Edition
· Approved on 29 September 2023 ·

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 3: Calculation procedures regarding adaptive building envelope elements

Thermal insulation of buildings
Including energy efficiency of buildings

ISO 52016-3:2023 Files

English 55 Pages
Current Edition
84.29 BHD

ISO 52016-3:2023 Scope

This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.

The three types of adaptive building envelope elements covered in this document are:

     building envelope elements with dynamic solar shading;

     building envelope elements with chromogenic glazing;

     building envelope elements with an actively ventilated cavity.

Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.

This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.

It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building.

In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.

This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.

NOTE            The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 2055-1:2016
GSO 2055-1:2015 
Bahraini Technical Regulation
HALAL FOOD - Part 1 : General Requirements
GSO 2055-1:2015
 
Gulf Technical Regulation
HALAL FOOD - Part 1 : General Requirements

Recently Published

ISO 24232:2024
 
International Standard
Protective clothing — Protection against rain
ISO 9241-920:2024
 
International Standard
Ergonomics of human-system interaction — Part 920: Tactile and haptic interactions
ISO 7683:2024
 
International Standard
Design criteria and test methods for removable shrink labels applied to PET bottles
ISO 7661:2024
 
International Standard
Aerospace fluid systems — Clamp blocks for tube lines having axial alignment — Design requirements and qualification testing (metric series)