ISO 52016-3:2023

International Standard   Current Edition
· Approved on 29 September 2023 ·

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 3: Calculation procedures regarding adaptive building envelope elements

Thermal insulation of buildings
Including energy efficiency of buildings

ISO 52016-3:2023 Files

null Pages
Current Edition

ISO 52016-3:2023 Scope

This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.

The three types of adaptive building envelope elements covered in this document are:

     building envelope elements with dynamic solar shading;

     building envelope elements with chromogenic glazing;

     building envelope elements with an actively ventilated cavity.

Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.

This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.

It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building.

In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.

This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.

NOTE            The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-1:2015
GSO 150-1:2013 
Bahraini Technical Regulation
Expiration dates for food products -Part 1 : Mandatory expiration dates
GSO 150-1:2013
 
Gulf Technical Regulation
Expiration dates for food products -Part 1 : Mandatory expiration dates

Recently Published

ISO 13615:2024
 
International Standard
Traditional Chinese medicine — Atractylodes macrocephala rhizome
ISO/IEC/IEEE 8802-15-4:2024
 
International Standard
Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 15-4: Wireless medium access control (MAC) and physical layer (PHY) specifications for low-rate wireless personal area networks (WPANs)
ISO/IEC 21122-1:2024
 
International Standard
Information technology — JPEG XS low-latency lightweight image coding system — Part 1: Core coding system
ISO/IEC 33202:2024
 
International Standard
Software and systems engineering — Core agile practices